Product description
H07V-U cable
The H07V-U is a low voltage electrical cable has solid copper core with PVC insulation, compliant with international standards. Designed for the interior wiring of the buildings, the connection of equipment and electrical distribution systems, It has a class copper driver 1 and flashy PVC insulation. With a nominal voltage of 450/750V, It is suitable for fixed installations in the conduits, Electric sheaths and cabinets, But is not designed for direct installation under plaster. In accordance with standards in 50525-2-31, IEC 60227 et AS/NZS 5000.1, It guarantees safety, Reliability and durability, which makes it a privileged choice for industrial and tertiary applications.
Construction
| Structure | Material |
| Driver | Rigid annealed copper, class 1 according to IEC 60228 |
| Isolation | PVC type TI1 according to DIN EN 50363-3 |
| Outer sheath | None |
| Driver class | Class 1 |
| Tension nominale | 450/750 V |
| Service temperature | 70°C |
| Colors available | Bleu, Brun, Noir, Gris, Rouge, Green/Yellow |
| Standards | IEC 60227, IEC 60228, IN 50525-2-31 |
| Application | Fixed installations in buildings, electrical panels and conduits |
Application
- Industrial equipment : Internal wiring of the machines, Electric control cupboards and equipment.
- Electrical installations of buildings : Passing in tubes, Equipped conduits and lighting systems.
- Distribution networks : Fixed installation in dry environments, For tables and distribution systems.
- Earthen : Green/yellow driver dedicated to the equipotential connection, Complies with safety standards.
- Confined environments : Pose in chute and conduits, Avoiding a protruding or outdoor installation.
- Noticed : Not adapted to direct installation on cable and cable trays, Except as an equipotentiality driver.
Standard
- Complies with BS EN50525-2-31 standards、IEC 60227、AS/NZS 5000.1
- Har certified, EAC, adapted to global requirements.
Properties
| Temperature range | Installation mobile : +5° C to +70 ° C |
| Installation fixe : -30° C to +80 ° C | |
| Tension nominale | U0/U AC 450/750 V |
| Test voltage | 2.5 kv |
| Minimal curvature radius | 6× exterior diameter of the cable |
| Installation temperature (minimum) | -5°C |
| Ambient temperature | -35° C to +35 ° C |
| Driver's maximum operating temperature | 70°C |
| Maximum short-circuit temperature | 160°C |
| Flame | IEC60332-1 |
| Isolation resistance | 10 MΩ·km |
| ZMS offers a tailor -made cable service, producing H07V-U cables according to your specifications and settings, In order to meet all your needs. | |
Features
The materials used during the manufacturing process are free from silicone and cadmium, and do not disturb the humidity of the paint layer.
Flower properties : Compliant with DIN VDE standard 0482-332-1-2 / YOUR ONE 60332-1-2 / IEC 60332-1-2.
Technical data
| AWG | Number of drivers x nominal section (1 x mm²) | Nominal thickness of insulation (mm) | Nominal external diameter (mm) | Nominal copper weight (kg/km) | Nominal cable weight (kg/km) |
| 20 | 1 x 0.5 | 0.6 | 2.1 | 4.8 | 9 |
| 18 | 1 x 0.75 | 0.6 | 2.2 | 7.2 | 11 |
| 17 | 1 x 1 | 0.6 | 2.4 | 9.6 | 14 |
| 16 | 1 x 1.5 | 0.7 | 2.9 | 14.4 | 21 |
| 14 | 1 x 2.5 | 0.8 | 3.5 | 24.0 | 33 |
| 12 | 1 x 4 | 0.8 | 3.9 | 38.0 | 49 |
| 10 | 1 x 6 | 0.8 | 4.5 | 58.0 | 69 |
| 8 | 1 x 10 | 1.0 | 5.7 | 96.0 | 115 |
Advantages of ZMS H07V-U cable
- Certification internationale : Complies with standards in/IEC/AS/NZS, Har certified, EAC, adapted to global requirements.
- Excellent performance : Flame (IEC 60332-1), Large temperature range (-35° C to +70 ° C), resistance to short circuits up to 160 ° C.
- Installation en conduit facilitée : Minimal curvature radius 6 × D, Compatible with the passage in conduits, Easy to pull and fix.
- High conductivity : Copper Copper Copper Class 1, 10mΩ isolation resistance · km, guaranteeing effective transmission.
- Adaptability : Available in 8 colors (rouge, bleu, Green/yellow for land setting, etc.). ZMS Cable also offers tailor -made cables to meet your specific needs.
H07V-K or H07V-U : which one to choose for your installation ?
Comparison between H07V-U and H07V-K
H07V-U and H07V-K meet different needs. None is inherently better than the other : the choice depends mainly on installation constraints, the level of flexibility required and the final application.
| Criteria | H07V-U | H07V-K |
| Driver type | Rigide monobrin (Class 1) | Flexible multi-strand (Class 5) |
| Flexibility | Weak | High |
| Usage principal | Fixed installation in conduit or surface | Internal wiring of panels and cabinets |
| Easy to install in a panel | Difficult to bend in tight spaces | Recommended, easy to walk |
| Conduit installation | Recommended | Possible but less common |
| Risk of breakage by bending | High if repeated bending | Weak |
| Prix | Slightly lower | Standard |
| Standards | IN 50525-2-31 | IN 50525-2-31 |
| Benefits | Excellent mechanical strength in fixed installation | Great handling flexibility |
| Widely used in residential and tertiary buildings | Easy installation in congested conduits | |
| Lower purchasing cost | Better resistance to vibrations and movements | |
| Simple connections for standard installations | Suitable for electrical cabinets and panels | |
| Economical solution for long cabling distances | Reduced risk of breakage during repeated bends |
Which cable to choose ?
| Application | Recommended cable |
| Residential electrical installation | H07V-U |
| Fixed distribution networks | H07V-U |
| Electric Tables | H07V-K |
| Control cabinets | H07V-K |
| Passages with many bends | H07V-K |
| Installations subject to vibrations | H07V-K |
| Projects requiring an economical solution | H07V-U |
ZMS Consulting : For internal wiring of a panel or electrical cabinet, le H07V-K is systematically recommended : its flexibility facilitates routing between components and reduces the risk of conductor breakage during maintenance interventions. And H07V-U is preferable for fixed installation in conduit or surface, where the rigidity of the conductor facilitates insertion into the sheaths and guarantees superior mechanical strength. When in doubt, the H07V-K remains the more versatile choice of the two.
H07V-U ou NYY : quel câble choisir ?
| Criteria | H07V-U | Nyy |
| Structure | Monoconductor, massive soul (class 1) | Multiconductors, âmes classe 1 or 2 |
| Outer sheath | Aucune — isolation PVC seule | Oui — gaine PVC de protection mécanique |
| Recommended installation | Sous conduit, goulotte ou tableau uniquement | Apparent, en caniveau, ou sous fourreau |
| Mechanical protection | Doit être assurée par le conduit | Intégrée à la gaine |
| Weather resistance | Non — pose intérieure/conduit uniquement | Oui — adapté à une exposition extérieure protégée |
| Available section | 1,5 has 400 mm² | 1,5 has 300 mm² |
| Prix | Standard | Slightly higher (sheath + matière première) |
| Standards | IN 50525-2-31 (IEC 60227) | IEC 60502-1, From vde 0276-604 |
| Typical applications | Câblage interne de tableaux, cupboards | Distribution d’énergie, alimentation posée directement |
ZMS Consulting : Optez pour le H07V-U lorsque le conduit ou le tableau assure déjà la protection mécanique — c’est la solution la plus économique. Opt for le NYY dès que le câble doit être posé sans conduit supplémentaire, en apparent ou en fourreau, où sa gaine intégrée devient indispensable.