Lyyy cable

LiYCY Cable——Double Shielded Cable + flexible cable

  • Anti-interference transmission : Tired copper braided armor + aluminium, Double protection against electromagnetic interference.
  • Flexibility and flexion resistance : Ultra-fine copper drivers + High flexibility PVC sheath, Rame of curvature reduced to 6 times the diameter.
  • Industrial application : Compatible with robots, automated lines and instrument control, transmission without signal loss.
  • Design compact : Diameter reduced to 3.6 mm, ideal for tight spaces.
  • Flame retardant and oil resistant : Compliant with IEC standard 60332-1, resists oils and chemicals.
  • ZMS Cable Customization Service : Color, number of drivers, custom length and shielding, complies with UL/CE/VDE standards.

Get a Quote

Description of LiYCY cable

The LiYCY cable is a CE certified industrial shielded cable, designed for environments with high electromagnetic interference. It incorporates an oxygen-free copper conductor and double tinned copper shielding (individual shielding + overall shielding) for effective protection against disturbances. Ideal for high-precision data transmission in industrial equipment and measuring instruments, it offers a small outer diameter as well as resistance to oils and chemicals. With a temperature range of -5°C to +70°C, it provides a reliable solution for dry and humid indoor environments.

LiYCY cable construction

Component Details
Driver Material : Oxygen-free copper wire strands (Compliant with IEC 60228 Class 5)
Features : High flexibility, suitable for applications with frequent movements, excellent resistance to bending fatigue.
Isolation Material : PVC (Vinyl polychloride)
Thickness : 0,6-0,8 mm (adjusted according to the section)
Function : Provides basic electrical insulation, dielectric strength ≥ 20 kV/mm.
Shielding Structure : Aluminum foil + tinned copper braid (coverage rate ≥ 85 %)
Role : Effective double shielding against electromagnetic interference (EMI) and radio frequencies (RFI).
Sheath Material : Special modified PVC
Properties : Oil resistant, UV, flame delayer (compliant with IEC vertical combustion test 60332-1).

Applications of LiYCY cable

Recommended Applications

Connecting servomotors to drives (respect the radius of curvature).

Industrial Ethernet networks (take into account the voltage drop in case of PoE power supply).

Signal transmission in medical equipment (thanks to its low electromagnetic interference).

Limitations d'utilisation

Avoid parallel installation with high voltage cables >10kV (minimum distance of 30 cm).

UV protection required for prolonged exposure (adding a protective sheath).

Standard

From vde 0285 Part 303; IEC 60228 Class 5/6; RoHS 3 (EU 2015/863); IEC 60332-1; IN 50288-7

Properties of LiYCY cable

Setting Typical value Technical analysis
Nominal section 0,5-2,5 mm² Small section design suitable for signal transmission, reducing losses due to skin effect.
Driver diameter 0,8-1,8 mm (monobrin) Twisted multi-strand structure with diameter tolerance controlled to ±0.02 mm.
DC resistance ≤39.0 Ω/km (0,5 mm²) Value measured at 20°C, increasing by 0,4 % per °C with temperature.
Tension nominale 300/300V Suitable for low voltage control systems, dielectric strength test ≥2000V/5min.
Current capacity 12A (0,5 mm², 30°C) Reference to the DIN VDE standard 0298-4, with a reduction in 15 % in an environment of 40°C.
Service temperature -30° C to +80 ° C (Installation fixe)
-5° C to +70 ° C (Pendant l’installation)
The sheath remains flexible at low temperatures, and the insulation resistance decreases by less than 5 % in increments of 10°C at high temperature.
Radius of curvature 6× exterior diameter of the cable For a dynamic installation, radius ≥8× outer diameter is recommended to extend service life.
Category Setting Description
Performance de transmission Ability 110-150 pF/m (1kHz), low capacitance design to reduce signal distortion.
Impedance 100±15Ω, suitable for transmitting differential signals such as RS485.
Mechanical characteristics Tensile strength ≥12,5 N/mm² (sheath), supports more than 2000 flexion cycles.
Abrasion resistance Complies with the standard in 50396 with more than 10 000 drum friction test cycles.
Environmental adaptability Chemical resistance ISO compliant 1817, resistant to industrial oils and diluted acid/base solutions (<10%).
Fire classification Complies with IEC standards 60332-1 / IN 50265-2-1, flame spread ≤1.5 m.
Performance CEM (Electromagnetic compatibility) Shielding Effectiveness Mitigation >60 dB over a frequency range of 30MHz to 1GHz, Complies with the standard in 50289-1-6.

Technical data

ZMS Cable Customization Service : Color, number of drivers, custom length and shielding structure, compliant with UL/CE/VDE standards.

  • Color customization : Available according to DIN standard 47100 or with a company-specific color code.
  • Flexible number of conductors : Of 2 has 61 drivers, with an optimized outer diameter to accommodate equipment interfaces.
  • Certified compliance : Supply of UL/CE/VDE certificates, guaranteeing use in international markets.

LiYCY Cable Specifications

Number of conductors X Nominal section (mm²) Poids nominal (kg/km) Maximum outside diameter (mm)
1 x 0.14 16 3.6
1 x 0.25 17 3.1
2 x 0.14 20 3.8
2 x 0.25 30 4.5
2 x 0.34 33 5.0
2 x 0.5 42 5.4
2 x 0.75 56 6.7
2 x 1 84 7.7
2 x 1.5 97 8.1
2 x 2.5 148 10.1
3 x 0.14 25 4.0
3 x 0.25 37 5.1
3 x 0.34 42 5.4
3 x 0.5 51 5.8
3 x 0.75 70 7.1
3 x 1 110 8.5
3 x 1.5 125 8.9
3 x 2.5 188 10.6
3 x 4 250 12.4
3 x 6 285 13.9
4 x 0.14 30 4.3
4 x 0.25 44 5.2
4 x 0.34 49 5.8
4 x 0.5 61 6.5
4 x 0.75 95 7.6
4 x 1 130 9.2
4 x 1.5 165 9.7
4 x 2.5 236 11.6
4 x 4 302 13.5
4 x 6 412 15.2
4 x 10 620 20.8
4 x 16 1090 23.2
4 x 25 1787 28.2
4 x 35 2142 31.5
5 x 0.14 36 4.6
5 x 0.25 51 5.7
5 x 0.34 59 6.1
5 x 0.75 130 8.2
5 x 1 156 9.9
5 x 1.5 193 10.5
5 x 2.5 270 12.6
5 x 4 370 14.8
5 x 6 505 16.7
5 x 10 796 22.9
5 x 16 2070 25.6
5 x 25 2047 31.1
6 x 0.14 40 5.0
6 x 0.25 55 6.1
6 x 0.34 64 6.6
7 x 0.14 41 5.2
7 x 0.25 60 6.4
7 x 0.34 69 6.7
7 x 0.5 98 7.8
7 x 0.75 168 8.9
7 x 1 192 10.7
7 x 1.5 245 11.3
7 x 2.5 340 13.7
7 x 4 473 16.1
8 x 0.14 44 5.6
8 x 0.25 77 7.1
8 x 0.34 84 7.4
10 x 0.14 56 6.3
10 x 0.25 93 8.1
10 x 0.34 106 8.5
12 x 0.14 60 6.4
12 x 0.25 104 8.4
12 x 0.34 119 8.7
12 x 0.5 156 10.1
12 x 0.75 232 12.0
12 x 1 265 13.7
12 x 1.5 365 14.5
12 x 2.5 585 18.5
14 x 0.14 65 6.7
14 x 0.25 115 8.7
14 x 0.34 132 9.1
16 x 0.14 81 7.2
16 x 0.25 132 8.9
16 x 0.34 146 9.6
18 x 0.14 93 7.6
18 x 0.25 137 9.4
18 x 0.34 188 10.1
18 x 0.5 215 11.8
18 x 0.75 315 13.9
18 x 1 380 15.9
18 x 1.5 553 16.9
21 x 0.14 103 8.3
21 x 0.25 173 10.4
21 x 0.34 193 10.9
24 x 0.14 117 9.0
24 x 0.25 184 11.4
24 x 0.34 213 12.0
25 x 0.14 120 9.0
25 x 0.25 190 11.5
25 x 0.5 314 14.4
25 x 0.75 418 16.5
25 x 1 475 17.5
25 x 1.5 720 20.1
27 x 0.14 124 9.1
27 x 0.25 198 11.6
27 x 0.34 232 12.3
30 x 0.14 136 9.4
30 x 0.25 212 11.9
30 x 0.34 253 12.7
30 x 0.75 500 18.0
30 x 1.5 776 20.7
36 x 0.14 160 10.0
36 x 0.25 238 12.7
36 x 0.34 292 13.6
40 x 0.14 170 10.3
40 x 0.25 260 13.1
40 x 0.34 318 14.0
44 x 0.14 186 11.1
44 x 0.25 290 14.3
52 x 0.14 200 11.5
52 x 0.25 333 14.9
52 x 0.34 400 15.8
61 x 0.14 250 12.1
61 x 0.25 382 15.8
61 x 0.34 454 16.6

LiYCY vs LiYY vs LiHCH

Features LiYCY LiYY (unshielded) LiHCH (high temperature)
Shield design Aluminum foil + copper braid (double shielded) None Copper braid
Temperature range -30℃ to +80 ℃ -30℃ to +70 ℃ -60℃ at +180 ℃
Oil resistance Protection IP67 Basic protection Resistant to high temperature oils
Typical applications Connecting frequency converters Internal wiring of control cabinets High Temperature Areas in Metallurgical Equipment

Main advantages of ZMS LiYCY cable

Excellent protection against interference : Double shielded structure (individual shielding + overall shielding), Significantly reducing electromagnetic interference and internal crosstalk.

Installation flexible : Minimum bending radius of 12× the outer diameter in mobile installation. Minimum bending radius of 6× the external diameter in fixed installation. Small outer diameter, optimizing space, ideal for restricted environments.

Great environmental adaptability : Wide operating temperature range. Suitable for dry environments, damp and wet.

Ready to use : Support for pre-installed connectors, rapid deployment in dry or humid environment.

Flame retardant and oil resistant : Compliant with IEC standard 60332-1, resists oils and chemicals.

Safety and reliability : Anti-flame properties according to IEC standard 60332-1, guaranteeing better protection in the event of fire.

    Request a free quote, we will respond to you within 24 hours.

    Your Name*:

    Your Email*:

    Your Phone*:

    Your Country:

    Your message*: