- Flexible, Cold -resistant, Ozone resistant
- Electric cable/Copper cables/Flexible cables/Low voltage cables
- Har certified, EAC, Complies with DIN VDE standards 0285-525-2-21 and in 50525-2-21.
- ZMS Cable offers personalized H05RR-F cables. Suitable for your needs, They meet all your specific requirements.
Product description
The H05RR-F is a flexible multi-core cable with rubber insulation and jacket, designed for environments with low mechanical stress. It is intended for the connection of household appliances, office equipment and light tools (such as vacuum cleaners, kitchen appliances, portable lamps, etc.). Its nominal voltage is 300/500V, complies with harmonized European standards (certification HAR). Offering both flexibility and durability, it can be used in dry environments, wet or outdoors, for temporary applications. The EPR rubber material gives it excellent resistance to weather and wear, making it a versatile power connection solution for homes, cuisines, offices and other similar environments.
Meaning of the letters of the H05RR-F cable
- H – Harmonized type
- 05 – Tension nominale 300/500 V
- R – Rubber sheath
- R – Rubber insulation
- F – Soft conductors (flexible)
Construction
Drivers : Cu, class 5 according to EN standard 60228
Isolation : Rubber compound, type NO 4 according to EN standard 50363-1
Sheath : Rubber compound, type EM 3 according to EN standard 50363-2-1
If you need shielding, contact ZMS Cable for a tailor-made solution. For more information on shielding, see below.
Application
1. Household appliances : Power connection for vacuum cleaners, electric kettles, ovens and other kitchen equipment as well as small portable appliances.
2. Office equipment : Secure power supply for printers, computers and other devices with low load.
3. Lightweight tools : Mobile power cables for garden tools, drills and other devices used in low mechanical stress environments.
4. Extension cables : Extension cables for temporary lighting or exterior outlets, to be used in conditions of low mechanical stress.
5. Humid environments : Connecting equipment in damp areas such as bathrooms or basements (not intended for prolonged use underwater).
Standard
Har certified, EAC, Complies with DIN VDE standards 0285-525-2-21 and in 50525-2-21.
Properties
| Test voltage | 2 kV |
| Tension nominale | 300/500 V |
| Minimum installation temperature | -25°C |
| Maximum driver temperature | 60°C |
| Maximum short-circuit temperature | 200°C |
Technical data
| Nominal section | Maximum Resistance At 20°C | Max Diameter. Wires in the Flange | Nominal Insulation Thickness | Nominal Coating Thickness | Outside Diameter (Approx.) | Cable Weight (Approx.) |
| mm² | Ω/km | mm | mm | mm | kg/km | |
| 2 x 0,75 | 26,0 | 0,21 | 0,6 | 0,8 | 6,2 | 52 |
| 2 x 1,0 | 19,5 | 0,21 | 0,6 | 0,9 | 6,8 | 61 |
| 2 x 1,5 | 13,3 | 0,24 | 0,8 | 1,0 | 8,2 | 94 |
| 2 x 2,5 | 7,98 | 0,24 | 0,9 | 1,1 | 9,8 | 137 |
| 2 x 4,0 | 4,95 | 0,28 | 1,0 | 1,2 | 11,8 | 165 |
| 3 x 0,75 | 26,0 | 0,21 | 0,6 | 0,9 | 6,8 | 64 |
| 3 x 1,0 | 19,5 | 0,21 | 0,6 | 0,9 | 7,2 | 73 |
| 3 x 1,5 | 13,3 | 0,24 | 0,8 | 1,0 | 8,7 | 112 |
| 3 x 2,5 | 7,98 | 0,24 | 0,9 | 1,1 | 10,4 | 166 |
| 3 x 4,0 | 4,95 | 0,28 | 1,0 | 1,2 | 12,5 | 234 |
| 3 x 6,0 | 3,30 | 0,28 | 1,0 | 1,4 | 14,4 | 319 |
| 4 x 0,75 | 26,0 | 0,21 | 0,6 | 0,9 | 7,4 | 77 |
| 4 x 1,0 | 19,5 | 0,21 | 0,6 | 0,9 | 7,8 | 89 |
| 4 x 1,5 | 13,3 | 0,24 | 0,8 | 1,1 | 9,7 | 140 |
| 4 x 2,5 | 7,98 | 0,24 | 0,9 | 1,2 | 11,6 | 207 |
| 4 x 4,0 | 4,95 | 0,28 | 1,0 | 1,3 | 13,9 | 293 |
| 4 x 6,0 | 3,30 | 0,28 | 1,0 | 1,5 | 16,0 | 400 |
| 5 x 0,75 | 26,0 | 0,21 | 0,6 | 1,0 | 8,2 | 98 |
| 5 x 1,0 | 19,5 | 0,21 | 0,6 | 1,0 | 8,8 | 113 |
| 5 x 1,5 | 13,3 | 0,24 | 0,8 | 1,1 | 10,6 | 172 |
| 5 x 2,5 | 7,98 | 0,24 | 0,9 | 1,3 | 12,9 | 260 |
| 5 x 4,0 | 4,95 | 0,28 | 1,0 | 1,4 | 15,5 | 374 |
Points techniques
1. Certification standards : Har certified, EAC, Complies with DIN VDE standards 0285-525-2-21 and in 50525-2-21.
2. Structural design : Black rubber sheath (material EM3), minimum radius of curvature of 7,5 times the outside diameter, oil and water resistant.
3. Voltage range : Tension maximale alternative 550V / continue 825V, test voltage 2000V (driver to driver).
4. Driver Specifications : From 0,75 mm², finely stranded bare copper conductor (Class 5), allowing flexible installation.
Differences between H05RR-F and H05VV-F cables
| Features | H05RR-F | H05VV-F |
| Materials' cost | Pupil (more complex rubber manufacturing) | Bas (PVC easier to produce) |
| Temperature range | -30°C to +60°C | -5° C to +70 ° C |
| Resistance to mechanical stress | Forte (adapted to frequent flexions) | Average (Avoid high voltages) |
For more details, see H05RR-F vs H05VV-F : which best suits your needs ? ZMS Cable, as a professional cable supplier, offers tailor-made solutions adapted to the needs of its customers. For technical details or case studies, contact our team of experts and receive exclusive technical documentation !
Cable H05RR-F : Shielding Options and Applications
1. Standard design of H05RR-F
No shielding by default : The classic version of the H05RR-F (ex. : H05RR-F 3×1.5mm²) does not have a shielding layer. Its structure consists only of conductors + isolation an EPR + neoprene sheath, according to EN standard 50525-2-21.
For what ? : H05RR-F is mainly used in industrial machinery and temporary power supplies, where protection against electromagnetic interference (EMI) is generally not necessary.
2. Custom shielding options
Addition of possible shielding :
- Braided shield : A tinned copper braid is added around the insulation (coverage rate ≥ 80 %), ensuring attenuation up to 60 dB to 1 MHz.
- Suitable applications : Power supply of precision instruments and high frequency equipment (ex. : machines CNC, medical devices).
Model identification : Armored versions are usually marked H05RR-F-S (the “S” meaning “Shielded”). It is important to clarify this requirement with the supplier.
3. Comparison between shielded and unshielded cables
| Features | H05RR-F-S (Armored) | H05RR-F (Unlissed) |
| Protection against interference | Forte (EMI mitigation <30 MHz) | Weak |
| Cost | Environ 25 % higher (ZMS tariff reference 2023) | Standard |
| Radius of curvature | 9 × Ø (limited by the braid) | 7.5 × Ø |
4. When to choose the armored version ?
Recommended scenarios : The cable is installed parallel to frequency converters, powerful motors or other sources of electromagnetic disturbance.
It powers sensors or communication lines, where signal noise reduction is required.
Alternative : For a higher level of shielding, it is possible to opt for a CY shielded cable (ex. H07RN-F), but with an increase in cost of 40 %.
5. Services ZMS Cable
- Tailor-made solutions : Manufacture of shielded H05RR-F-S cables with tinned copper braid or aluminum shielding according to requirements.
- Free tests : EMC performance verification (EMI shielding) in the laboratory, over a frequency range of 10 kHz to 1 GHz.
Need technical specifications or a quote ? Send your application details to the ZMS Cable technical team !
Advantages of the H05RR-F cable
1. Wide adaptability : EPR rubber insulation and jacket, temperature resistant from -25°C to +60°C, suitable for dry/humid environments and temporary outdoor use.
2. Safe and reliable : Certified according to international standards such as DIN VDE, IEC, with excellent fire resistance properties (IN 60332-1-2), guaranteeing electrical safety.
3. Flexible et durable : Finely stranded bare copper conductor (Class 5) with optimized twist pitch design, resistant to wear and aging during repeated bending, ideal for mobile equipment.
4. Multiple configurations available : Offered in versions 2 has 5 drivers, with or without yellow/green protective conductor (GN-YE), meeting a wide range of needs.
5. Economical and efficient : Lightweight design offering a good compromise between performance and cost, ideal for domestic and light commercial applications.