- NYY - - Low voltage electric cables
- ZMS Cable offers tailor -made cable services to meet all your needs.
Product description
The NYY cable is a low voltage power cable in accordance with the German standard VDE 0276-603. It is designed for fixed installations (underground, interior, conduits) with double insulation in PVC (Driver insulation + PVC outdoor sheath).
It is available in two versions : Ny-j, with protective driver (ex. : 5×6 pour 5 drivers of 6 mm² each), et nyy-o, without protective driver.
Its performance includes UV resistance, humidity and chemicals, guaranteeing excellent sustainability in industrial environments, Electrical installations of renewable buildings and power plants.
The driver is copper (Some aluminum variants), With full structures (RE) or torthus (RM), combining conduction efficiency and installation flexibility.
Construction
Naked copper driver | Solid wire in accordance with DIN VDE 0295 cl.1 / IEC 60228 cl.1 |
Multibrin wire compliant with DIN VDE 0295 cl.2 / IEC 60228 cl.2 | |
Driver insulation | PVC, Div4 compound type, Compliant with HD 603 S1 |
Driver identification | Compliant with DIN VDE 0293-308 / 0276-603 |
DRUTION OF CONDUCTORS | Cabinated in concentric layers |
Outer sheath | PVC, DMV5 compound type, Compliant with HD 603 S1 |
Sheath color | Mainly black (customizable) with chemical resistance, flame delayer and without harmful substances (Compliant with the ROHS standard). |
Color coding | 1 has 5 drivers : Color coding according to VDE0293 standard (For example, noir, marron, etc.). |
From 6 drivers and more : Digital coding identification. | |
Model differences | Ny-j : With yellow-green earth driver, Suitable for applications requiring reliable earth (For example, underground, underwater, or in outdoor sites). |
NYY-O. : landless, Suitable for other applications or existing independent earthquake systems. |
Standard
HD 603 S1, IEC 60502-1, VDE 0276-603 HD 603 S1, IEC 60502-1, VDE 0276-603
Meaning of letters
N : Standardized cable compliant with the German VDE standard 0276-603.
YY : PVC insulation and sheath (double isolation : PVC drivers + PVC outdoor sheath).
J / o :
Ny-j : With two-color-green bicolor protective driver (terre), adapted to the installations requiring an earth.
NYY-O. : Without protective driver, Used for other applications.
Driver types
RE : Massive round driver
RM : Toronne round driver
SM : Conducteur sectoral toronné
Properties
Paramètres principaux | |
Tension nominale | 0.6/1 kV (Compliant with IEC standard 60502-1). |
Test voltage | 4000V (AC, 50Hz). |
Temperature range | |
Installation temperature | -5°C à +50°C |
Température en service fixe | -40° C to +70 ° C |
Maximum short-circuit temperature | 160°C |
Conductor material | Copper (class 1 or 2 According to the section). |
Fire resistance | Compliant with IEC standard 60332-1-2 (test de propagation verticale de la flamme sur un seul câble). |
Courant de court-circuit | 0.46 kA pendant 1 seconde (exemple pour une section de 4 mm²) |
Caractéristiques de construction | |
Isolation | PVC DIV4 (résistant aux agents chimiques). |
Sheath | PVC DMV5 (principalement noir, Other colors on request) |
Radius of curvature | Monoconductor : 15 × Ø extérieur |
Multiconductor : 12 × Ø extérieur |
Technical data
Câble Nyy
Section(mm²) | Torons | Nominal thickness of insulation (mm) | Épaisseur nominale de l’revêtement (mm) | Diamètre prévu (mm) | Poids prévu (kg/km) | Capacité de courant en pose enterrée (A) | Capacité de courant en pose à l’air libre (A) | Capacité de courant en pose en conduit (A) |
1 x 6 | 7 | 1 | 1.4 | 7.90 | 112 | 72 | 54 | 58 |
1 x 10 | 1 | 1 | 1.4 | 8.50 | 150 | 95 | 74 | 77 |
1 x 16 | 7 | 1 | 1.4 | 9.70 | 222 | 127 | 100 | 102 |
1 x 25 | 7 | 1.2 | 1.4 | 11.3 | 330 | 163 | 131 | 132 |
1 x 35 | 7 | 1.2 | 1.4 | 12.3 | 431 | 195 | 161 | 157 |
2 x 6 | 1 | 1 | 1.8 | 15.9 | 378 | 68 | 48 | 56 |
2 x 10 | 1 | 1 | 1.8 | 17.5 | 500 | 90 | 66 | 75 |
2 x 16 | 7 | 1 | 1.8 | 18.7 | 650 | 116 | 89 | 95 |
2 x 25 | 7 | 1.2 | 1.8 | 22.0 | 945 | 145 | 118 | 120 |
2 x 35 | 7 | 1.2 | 1.8 | 24.0 | 1210 | 175 | 145 | 145 |
NYY-J cable
Model | Number of drivers | Section (mm²) | Niveau de tension (kV) | Outer diameter (mm) | Weight (kg/km) |
NYY-J 1×1.5 | 1 | 1.5 | 0.6/1 | 5.5 | 35 |
NYY-J 2×1.5 | 2 | 1.5 | 0.6/1 | 9 | 70 |
NYY-J 3×2.5 | 3 | 2.5 | 0.6/1 | 11 | 120 |
NYY-J 4×4 | 4 | 4 | 0.6/1 | 13.5 | 200 |
NYY-J 3×6+1×4 | 4 | 6 (3 cores) + 4 (1 core) | 0.6/1 | 14.5 | 250 |
NYY-J 5×10 | 5 | 10 | 0.6/1 | 18 | 400 |
NYY-J 1×25 | 1 | 25 | 0.6/1 | 10.5 | 150 |
NYY-J 3×35+1×16 | 4 | 35 (3 cores) + 16 (1 core) | 0.6/1 | 22 | 600 |
NYY-J 4×50 | 4 | 50 | 0.6/1 | 25 | 800 |
NYY-J 1×95 | 1 | 95 | 0.6/1 | 16.5 | 350 |
NYY-J 3×120+1×70 | 4 | 120 (3 cores) + 70 (1 core) | 0.6/1 | 32 | 1200 |
Comparison of NYY-J and NYY-O cables
Comparison criterion | Ny-j | NYY-O. |
Protective driver | Includes a yellow-green earth thread (protective driver), offering additional protection | No protective driver, requires a connection to the earth by other means |
Identification of conductors' colors | Yellow-green earth thread + Other color threads (For example, brun, noir, gris) | Blue neutral thread (so present) + Other color threads (For example, brun, noir, gris) |
Driver type | Solid driver (RE), twisted driver (RM) or sector -shaped driver (SM), According to the transverse section chosen | Identical to NYY-J, The type of driver is determined by the transverse section |
For more details, see " Underground and underwater use : NYY cable analysis. »
Popular NYY cable models
Number of drivers | Models | Example | Tension |
Unipolar cable | Ny-j 1x… | Ny-j 1 × 50 (designates a single driver with a section of 50 mm²). | 0,6/1 kV (basse tension) |
Multipolar cable | Ny-j 2x… nyy-j 3x… nyy-j 4x… nyy-j 5x… | Ny-J 3 × 25+1 × 16 (noted 3 phase conductors 25 mm² and 1 earth driver 16 mm²). | |
Special models : NYY-O CHOR ROND; Nyy-j cable with earth driver. |
Applications principales
Industrial environments : Electrical connection of factory equipment (Resistance to severe environments)
Rail transport : Metro/tram rail supply
Renewable energies : Energy transmission for wind and solar
Construction sites : Temporary power supply installation
Domestic wiring : Interior electrical systems (requiring moisture protection)
Benefits
1. Double sheath for maximum protection
PVC double sheath design : External layer resistant to mechanical shock and UV, Internal layer strengthening insulation. Reliable performance even in demanding environments (humidity, dust, exterior installations).
2. Certified safety and strict compliance
Compliant with IEC standard 60332-1 In terms of flame delay : auto-extinguible, does not spread the fire. The NYY-J version incorporates a green/yellow earth driver, ensuring better protection against electric leaks, Ideal for secure installations in the building.
3. High -end materials for optimal performance
Copper or aluminum drivers (Excellent conductivity and corrosion resistance), isolation in PVC or XLPE (supports temperatures from 70 ° C to 90 ° C), extending the lifespan of 30 % Compared to standard cables.
4. Application versatility
Compatible with various environments : industrial machines, railway infrastructure, Renewable energy power plants, construction sites and domestic installations. Suitable for low and medium voltage applications (0,6/1 kV).
5. Flexible and optimized installation
Flexible PVC facilitating bending, increasing the efficiency of the wiring of 50 % in complex structures. Suitable for fixed installations as well as semi-mobile applications.
6. Guaranteed manufacturing and reliability excellence
Rigorous quality control of the raw material to the finished product. Bubble -free extrusion process, 4000V dielectric hold test, fault rate below 0,01 %.