Liyy cable

  • Liyy High Flexibility cable | Customized industrial solution ZMS CABLE
  • Expert in twisted multiconductor signal transmission | Flame-retardant PVC sheath
  • Resistance to oils and chemicals
  • Compact and lightweight design | Data transmission for industrial automation | Connection of laboratory equipment
  • EC certification certification

Get a Quote

Product description

LiYY cable is an unshielded cable, multi-conductor and flame-retardant PVC, designed for data transmission. It is mainly used in industrial automation fields, Electronic equipment, computer systems as well as measurement and control devices. This cable is particularly suitable for applications requiring a reduced external diameter.

Its typical structure includes a thin, multi-stranded copper conductor, PVC insulation and PVC sheath, offering great flexibility and a small outer diameter. It is ideal for use in tight spaces or in installations requiring frequent movement. This cable is resistant to oils and chemicals and operates stably in dry or humid indoor environments (temperature range in mobile installation : -5 °C to 80 °C). Complies with international DIN standards, VDE, CE, it is suitable for European and North American markets.

Construction

Component Technical specifications
Driver Oxygen-free copper (OFC), purity ≥99.99%
Ultrafine strands (diameter ≤0.2 mm per wire)
Compliant with IEC standard 60228 Class 5
Isolation PVC complies with DIN VDE standards 0207-363-3 / YOUR ONE 50363-3 (compound type TI2)
Thermal aging test according to IEC 60811-1-1 (135°C × 168h)
Sheath PVC complies with DIN VDE standards 0207-363-4-1 / YOUR ONE 50363-4-1 (type of compound TM2)
Flame resistance test according to IEC 60332-1-2

Application

  • Industrial automation : Control panels, electronic scales, transmission of sensor signals.
  • Electronic equipment : Computer systems, measuring instruments, internal connections of office equipment.
  • Low voltage applications : Unpowered signal transmission in tool manufacturing and mechanical control systems.
  • Laboratories and production lines : Cabling for data acquisition and control in dry or humid indoor environments.

Standard

VDE standards-0812 & 0814, FROM 47414; Directive Basse Tension CE 2014/35/UE; RoHS Compliance

Settings

Temperature range Flexible : -5° C to +80 ° C
Fixe : -40° C to +80 ° C
Maximum operating voltage 0,14 mm² : 350 V
0,25 – 1,5 mm² : 500 V
(Not intended for high current installations)
Test voltage between conductors 0,14 – 0,25 mm² : 1200 V
0,34 – 1,5 mm² : 2000 V
Breakdown voltage 0,14 – 0,25 mm² : 2400 V
0,34 – 1,5 mm² : 4000 V
Mutual capacitance between conductors (has 800 Hz) 0,14 – 0,25 mm² : env. 100 pF/m
0,34 – 1,5 mm² : env. 150 pF/m
Characteristic impedance 78 Oh (approximate value)
Inductance Env. 0,65 MH/KM
Minimal curvature radius Flexible : 7,5 x external Ø
Fixe : 4 x external Ø

Technical data

Number of conductors × Section (mm²) AWG equivalent (appro x.) External diameter (mm, appro x.) Weight of copper per km (kg) Weight (kg/km, appro x.)
2 x 0.14 26 3.2 2.7 13.0
3 x 0.14 26 3.4 4.0 16.0
4 x 0.14 26 3.6 5.4 19.0
5 x 0.14 26 3.9 6.7 22.0
6 x 0.14 26 4.4 8.1 25.0
7 x 0.14 26 4.4 9.4 28.0
8 x 0.14 26 5.0 10.7 35.0
10 x 0.14 26 5.4 13.4 41.0
12 x 0.14 26 5.6 16.1 48.0
14 x 0.14 26 6.0 18.8 53.0
16 x 0.14 26 6.3 21.5 59.0
18 x 0.14 26 6.6 24.2 65.0
20 x 0.14 26 6.9 26.9 70.0
21 x 0.14 26 6.9 28.2 77.0
24 x 0.14 26 7.8 32.3 87.0
25 x 0.14 26 7.8 33.6 91.0
27 x 0.14 26 7.8 36.3 97.0
30 x 0.14 26 8.2 40.3 108.0
32 x 0.14 26 8.5 43.0 114.0
36 x 0.14 26 8.8 48.4 126.0
40 x 0.14 26 9.7 54.0 139.0
42 x 0.14 26 9.7 56.0 146.0
44 x 0.14 26 10.0 59.0 153.0
48 x 0.14 26 10.2 65.0 164.0
52 x 0.14 26 10.4 70.0 173.0
56 x 0.14 26 10.9 75.0 187.0
61 x 0.14 26 11.2 82.0 204.0
Number of conductors × Section (mm²) AWG equivalent (appro x.) Outer diameter (mm, appro x.) Weight of copper per km (kg) Weight (kg/km, appro x.)
2 x 0.25 24 3.8 4.8 18.0
3 x 0.25 24 4.0 7.2 22.0
4 x 0.25 24 4.5 9.6 26.0
5 x 0.25 24 4.9 12.0 30.0
6 x 0.25 24 5.3 14.4 36.0
7 x 0.25 24 5.3 16.8 42.0
8 x 0.25 24 6.3 19.2 49.0
10 x 0.25 24 6.8 24.0 57.0
12 x 0.25 24 7.0 28.8 66.0
14 x 0.25 24 7.3 33.6 75.0
16 x 0.25 24 7.9 38.4 84.0
18 x 0.25 24 8.3 43.2 94.0
19 x 0.25 24 8.3 46.0 98.0
20 x 0.25 24 8.7 48.0 103.0
21 x 0.25 24 8.7 50.0 107.0
24 x 0.25 24 9.8 60.0 120.0
25 x 0.25 24 9.8 61.0 132.0
27 x 0.25 24 9.8 65.0 140.0
30 x 0.25 24 10.3 72.0 156.0
32 x 0.25 24 10.9 77.0 164.0
36 x 0.25 24 11.3 86.0 182.0
37 x 0.25 24 11.3 89.0 190.0
40 x 0.25 24 12.4 96.0 200.0
42 x 0.25 24 12.4 101.0 211.0
44 x 0.25 24 12.8 106.0 225.0
48 x 0.25 24 13.0 115.0 245.0
52 x 0.25 24 13.3 125.0 263.0
56 x 0.25 24 13.7 134.0 280.0
61 x 0.25 24 14.3 146.0 305.0
Number of conductors × Section (mm²) AWG equivalent (appro x.) Outer diameter (mm, appro x.) Weight of copper per km (kg) Weight (kg/km, appro x.)
2 x 0.34 22 4.0 6.5 22.0
3 x 0.34 22 4.4 9.8 30.0
4 x 0.34 22 4.8 13.1 43.0
5 x 0.34 22 5.2 16.3 54.0
6 x 0.34 22 5.6 19.6 58.0
7 x 0.34 22 5.6 22.8 61.0
8 x 0.34 22 6.7 26.1 73.0
10 x 0.34 22 7.2 32.6 82.0
12 x 0.34 22 7.6 39.2 102.0
14 x 0.34 22 8.0 45.7 108.0
16 x 0.34 22 8.4 52.0 126.0
18 x 0.34 22 8.8 59.0 143.0
20 x 0.34 22 9.5 65.0 160.0
21 x 0.34 22 9.5 69.0 166.0
24 x 0.34 22 10.4 78.0 186.0
25 x 0.34 22 10.4 82.0 192.0
27 x 0.34 22 10.4 88.0 206.0
30 x 0.34 22 11.2 98.0 226.0
32 x 0.34 22 11.6 104.0 245.0
36 x 0.34 22 12.0 118.0 285.0
37 x 0.34 22 12.0 121.0 292.0
40 x 0.34 22 13.1 131.0 318.0
42 x 0.34 22 13.1 137.0 330.0
44 x 0.34 22 13.6 144.0 370.0
48 x 0.34 22 14.0 157.0 405.0
52 x 0.34 22 14.4 170.0 430.0
53 x 0.34 22 14.8 183.0 440.0
61 x 0.34 22 15.2 199.0 610.0
Number of conductors × Section (mm²) AWG equivalent (appro x.) Outer diameter (mm, appro x.) Weight of copper per km (kg) Weight (kg/km, appro x.)
2 x 0.5 20 4.8 9.6 40.0
3 x 0.5 20 5.1 14.4 46.0
4 x 0.5 20 5.5 19.2 55.0
5 x 0.5 20 6.2 24.0 64.0
6 x 0.5 20 6.7 28.8 73.0
7 x 0.5 20 6.7 33.6 81.0
8 x 0.5 20 7.9 38.4 97.0
10 x 0.5 20 8.6 48.0 116.0
12 x 0.5 20 8.9 58.0 135.0
16 x 0.5 20 10.0 77.0 168.0
20 x 0.5 20 11.3 96.0 213.0
24 x 0.5 20 12.6 116.0 241.0
30 x 0.5 20 13.3 144.0 303.0
40 x 0.5 20 15.8 192.0 391.0
2 x 0.75 19 5.3 14.4 47.0
3 x 0.75 19 5.6 21.6 54.0
4 x 0.75 19 6.3 29.0 66.0
5 x 0.75 19 6.9 36.0 80.0
7 x 0.75 19 7.7 50.0 110.0
8 x 0.75 19 8.8 58.0 125.0
10 x 0.75 19 9.8 72.0 148.0
12 x 0.75 19 10.1 86.0 176.0
16 x 0.75 19 11.4 115.0 220.0
20 x 0.75 19 12.8 144.0 276.0
2 x 1 18 5.6 19.2 56.0
3 x 1 18 6.1 29.0 71.0
2 x 1.5 16 6.8 29.0 75.0
3 x 1.5 16 7.2 43.0 90.0

Benefits

  • High flexibility design : Multi-core twisted pair structure combined with a thin, multi-stranded copper conductor, with a small radius of curvature (installation mobile : only 10×D). Ideal for tight spaces and high-motion applications.
  • Excellent resistance to environments : Flame-retardant PVC jacket, oil and chemical resistant, ensuring stable operation in dry or humid indoor environments (temperature range : -30 ℃ to +70 ℃ in fixed installation, -5 ℃ to +80 ℃ an installation mobile).
  • Small diameter and lightness : Optimized design to save installation space, suitable for applications with low mechanical stress (such as laboratories and production lines).
  • International certifications : Complies with CE standards, FROM, VDE, meeting the requirements of European and American markets.
  • ZMS Customization Service : Flexible options for conductor cross section, the color of the sheath (ex. gray RAL7032), the length, and much more, to accommodate various application needs.

    Request a free quote, we will respond to you within 24 hours.

    Your Email*:

    Your Name*:

    Your Country:

    Your Phone*:

    Your message*: