- Rapid responsiveness + Flexible customization, reduced project costs
- Global sourcing with professional technical support
- Complies with NFC/IEC standards and environmental requirements.
Product description
RVFV cable is an industrial cable whose full name is copper cable with PVC insulation and sheath. It is specially designed for environments exposed to risks of mechanical damage or attacks by rodents. Thanks to its robust sheath structure, it offers excellent abrasion resistance, to chemicals and interference. This cable is suitable for fixed installations in warehouses, factories, public lighting systems, and can even be used safely in potentially explosive areas, such as gas stations and flammable material warehouses. By ensuring stable transmission of energy or signals, while strengthening protection against physical attacks and harsh environments, RVFV is one of the most reliable cabling solutions for industrial applications.
Construction
| Drivers | Copper, class 1 or 2 according to EN 60228 |
| Isolation | XLPE (chemically crosslinked) |
| Inner sheath | Waterproof PVC sheath |
| Armor | Two galvanized steel strips |
| Outer sheath | PVC |
| Sheath color | Customizable according to your requirements |
| Unleaded | Oui |
| Conductor shape | Circular |
Application
- Fixed cabling for industrial factories and warehouses
- Zones ATEX : stations-service, chemical plants, explosive environments
- Public lighting and underground cable networks
- Power supply of mechanical equipment and automated systems
Standard
NF C 32-322
Settings
| Test voltage | 4 kV |
| Nominal tension uo / u (One) | 0,6/1 kV |
| Minimum installation temperature | -5°C |
| Maximum service temperature | 90°C |
| Maximum short-circuit temperature | 250°C |
| Operating temperature range | -10 at 60°C |
| Minimal curvature radius | Monopolar – 15D |
| Multipolar – 12D | |
| Mechanical resistance to shock | Excellent |
| Cable flexibility | Rigid |
| Fire resistance performance | C2, Complies with standard NF C 32-070 |
| Chemical resistance | Occasional resistance |
| Weather resistance | Excellent |
| Waterproofing | Intermittent water resistance |
| Packaging | Custom cut |
Technical data
| Nominal section mm² | Maximum resistance to 20 ℃ Ω/km | Air current capacity A | Ground Current Capacity A | Outer diameter (approx.) mm | Metal mass kg/km | Cable mass (approx.) kg/km |
| 2×1,5 | 12,1 | 26 | 37 | 10,9 | 28,8 | 278 |
| 2×2,5 | 7,41 | 36 | 48 | 11,9 | 48 | 330 |
| 2×4 | 4,61 | 49 | 63 | 12,8 | 76,8 | 393 |
| 2×6 | 3,08 | 63 | 80 | 13,8 | 115,2 | 475 |
| 2×10 | 1,830 | 86 | 104 | 16,0 | 192 | 643 |
| 2×16 | 1,150 | 115 | 136 | 18,1 | 307,2 | 857 |
| 2×25 | 0,727 | 149 | 173 | 21,5 | 480 | 1214 |
| 2×35 | 0,524 | 185 | 208 | 23,8 | 672 | 1527 |
| 2×50 | 0,387 | 192 | 206 | 27,0 | 960 | 1832 |
| 3×1,5 | 12,1 | 23 | 31 | 11,3 | 43,2 | 301 |
| 3×2,5 | 7,41 | 31 | 41 | 12,5 | 72 | 356 |
| 3×4 | 4,61 | 42 | 53 | 13,4 | 115,2 | 440 |
| 3×6 | 3,08 | 54 | 66 | 14,4 | 172,8 | 540 |
| 3×10 | 1,830 | 75 | 87 | 16,9 | 288 | 758 |
| 3×16 | 1,150 | 100 | 113 | 19,0 | 460,8 | 1010 |
| 3×25 | 0,727 | 127 | 144 | 22,7 | 720 | 1451 |
| 3×35 | 0,524 | 158 | 174 | 25,1 | 1008 | 11857 |
| 3×50 | 0,387 | 192 | 206 | 28,1 | 1440 | 2373 |
| 3×70 | 0,268 | 246 | 254 | 32,5 | 2016 | 3237 |
| 3×95 | 0,193 | 298 | 301 | 37,8 | 2736 | 4659 |
| 3×120 | 0,153 | 346 | 343 | 41,7 | 3456 | 5678 |
| 3×150 | 0,124 | 395 | 387 | 46,4 | 4320 | 6910 |
| 3×185 | 0,0991 | 450 | 434 | 50,4 | 5328 | 8352 |
| 4×1,5 | 12,1 | 23 | 31 | 12,1 | 57,6 | 337 |
| 4×2,5 | 7,41 | 31 | 41 | 13,2 | 96 | 410 |
| 4×4 | 4,61 | 42 | 53 | 14,3 | 153,6 | 510 |
| 4×6 | 3,08 | 54 | 66 | 15,5 | 230,4 | 627 |
| 4×10 | 1,830 | 75 | 87 | 18,3 | 384 | 891 |
| 4×16 | 1,150 | 100 | 113 | 20,8 | 614,4 | 1220 |
| 4×25 | 0,727 | 127 | 144 | 24,9 | 960 | 1769 |
| 4×35 | 0,524 | 158 | 174 | 27,6 | 1344 | 2264 |
| 4×50 | 0,387 | 192 | 206 | 30,9 | 1920 | 2908 |
| 4×70 | 0,268 | 246 | 254 | 37,4 | 2688 | 4424 |
| 4×95 | 0,193 | 298 | 301 | 41,8 | 3648 | 5732 |
| 4×120 | 0,153 | 346 | 343 | 46,2 | 4608 | 7035 |
| 4×150 | 0,124 | 395 | 387 | 51,2 | 5760 | 8535 |
| 4×185 | 0,0991 | 450 | 434 | 55,7 | 7104 | 10352 |
| 4×240 | 0,0754 | 538 | 501 | 63,3 | 9216 | 13282 |
| 4×300 | 0,0601 | 621 | 565 | 70,0 | 11520 | 16290 |
| 5×1,5 | 12,1 | 23 | 31 | 13,1 | 72 | 374 |
| 5×2,5 | 7,41 | 31 | 41 | 14,1 | 120 | 388 |
| 5×4 | 4,61 | 42 | 53 | 15,3 | 192 | 589 |
| 5×6 | 3,08 | 54 | 66 | 16,9 | 288 | 745 |
| 5×10 | 1,830 | 75 | 87 | 20 | 480 | 1061 |
| 5×16 | 1,150 | 100 | 113 | 22,6 | 768 | 1452 |
| 5×25 | 0,727 | 127 | 144 | 27,3 | 1200 | 2136 |
| 5×35 | 0,524 | 158 | 174 | 30,4 | 1680 | 2746 |
| 5×50 | 0,387 | 192 | 206 | 35,9 | 2400 | 3988 |
Allowable current for a multi-conductor cable installed in open air, ambient temperature = 30 °C.
Allowable current for multi-conductor cable buried in conduits, ground temperature = 20 °C, burial depth = 0,7 m, thermal resistivity of the soil = 2,5 K.m/W.
Benefits
- Haute protection : Abrasion resistant sheath + chemical resistance + protection against rodents, suitable for demanding environments.
- Safety and reliability : Suitable for flammable and explosive areas (like gas stations), complies with international safety standards.
- Transmission stable : Copper core + PVC insulation, ensuring efficient and stable transmission of energy/signal.
- Tailor -made service : ZMS offers personalized solutions (length, specifications, certifications) to precisely meet project needs.