- XLPE insulated rigid cables; Low voltage industrial cables
- TÜV, CE, RoHS, NF C 32-321, IN 60228
- Polyvalent : Adapted to industrial installations, tertiary and residential, indoors.
- Solid and resistant : Excellent mechanical resistance, Ideal for apparent installation, buried or in sheath.
- High security : Excellent electrical performance and reliable fire behavior.
- Easy pose : Flexible, Reduced curvature radius, adapted to large -scale sites.
- ZMS CABLE can customize the R2V cable according to your materials and specifications, in order to perfectly meet all your requirements.
Product description
The R2V cable is a low voltage energy cable intended for fixed installations. It consists of a copper conductor (class 1 or 2 According to the section), XLPE insulation, ensuring excellent thermal resistance, and a PVC outer sheath, resistant to UV and mechanical attack. In accordance with standards in 60228, NF C 32-321 and in 60332-1-2, it offers a reliable and durable solution for power supply.
It is used in the power circuits of residential buildings, tertiary and industrial, both indoors and outdoors or under buried duct.
ZMS CABLE supplies certified R2V cables, manufactured according to European standards, and offers a personalization service (sections, sheath colors, lengths, packaging) to meet the requirements of each professional installation.
Construction
| Structure | Description | Standards/Certifications |
| Conductor material | 1,5 has 4 mm² : full class copper 1 (multi-strand option class 2 on demand); ≥ 6 mm² : stranded copper class 2, max diameter of strands ≤ 0,4 mm | IEC 60228 Class 1/2 |
| Isolation material | Cross-linked polyethylene (XLPE), High temperature resistance, Chemical corrosion resistance | NF C 32-321 |
| Driver identification | Optional green/yellow earth wire; Multibrical drivers differentiated by colors like red, jaune, vert, bleu, brun, etc. | Standard in 60228 |
| Outdoor sheath material | PVC, black or gray (Customizable color), flame delayer, UV resistance | Standard in 60332-1-2 fire resistance |
Standards
NF C32-321, IEC 60502-1, IN 60228, TÜV, CE, RoHS, Fireproof according to the standard 60332-1
R2V cable applications
- Low voltage power distribution : ideal for domestic and industrial electrical installations, guaranteeing safe and stable transmission of electricity.
- Fixed circuits in buildings : perfect for electrical panels, sockets and lighting, offering robustness and reliability in fixed installations.
- Power supply of industrial equipment : suitable for industrial machines and devices, thanks to its resistance to moderate mechanical stress and high temperatures.
- Environments requiring reliability and security : maintains stable performance even under demanding conditions.
- Types of R2V cable installation : Installation in duct, conduit or cable tray, including in humid or semi-buried areas with appropriate protection.
Expert advice – ZMS Cable
For fixed installations requiring good mechanical resistance and excellent value for money, our experts recommend choosing the R2V cable. When flexibility is essential — particularly in electrical panels or compact connection areas — it is preferable to opt for a cable H07V-K. If your installation must be buried or exposed to external conditions, we recommend the use of a NYY-J cable, more suitable for harsh environments. Finally, in public spaces where fire safety is a priority, choose one R2V LSZH cable to reduce smoke and halogen emissions.
Thanks to the tailor -made solutions offered by ZMS Cable, you can quickly identify the electrical cable best suited to your application while controlling the costs of your project.
Settings
| Setting | Value / Specification |
| Tension nominale (U/U₀) | 0,6/1 kV |
| Temperature range in service | –25°C to +90°C |
| Maximum driver temperature | +90°C |
| Maximum short-circuit temperature (5 s) | +250°C |
| Minimal curvature radius | Rigid conductor (Class 1) : 10 × cable Ø Stranded conductor (Class 2) : 7,5 × cable Ø |
| Fire holder | Complies with EN 60332-1-2 |
| Humidity resistance | Good, but not suitable for prolonged immersion |
| UV resistance | Oui (black PVC sheath) |
| Mechanical resistance | High (good behavior against impact and crushing) |
| Installation methods | Interior / outside / façade / cable tray / under buried sheath |
Technical data
| Nominal section [mm²] | Maximum resistance at 20 ℃ [Ω/km] | Air current capacity [A] | Earth current capacity [A] | Outer diameter (max.) [mm] | Metal mass [kg/km] | Cable weight (approx.)[kg/km] |
| 1 x 4 | 4,16 | 44 | 54 | 6,8 | 38,4 | 81 |
| 1 x 6 | 3,08 | 56 | 67 | 7,0 | 57,6 | 102 |
| 1 x 10 | 1,830 | 77 | 89 | 7,8 | 96 | 148 |
| 1 x 16 | 1,150 | 102 | 115 | 8,7 | 153,6 | 213 |
| 1 x 25 | 0,727 | 138 | 148 | 10,2 | 240 | 316 |
| 1 x 35 | 0,524 | 170 | 177 | 11,3 | 336 | 423 |
| 1 x 50 | 0,387 | 207 | 209 | 12,8 | 480 | 583 |
| 1 x 70 | 0,268 | 265 | 256 | 14,4 | 672 | 793 |
| 1 x 95 | 0,193 | 325 | 307 | 16,2 | 912 | 1057 |
| 1 x 120 | 0,153 | 380 | 349 | 17,8 | 1152 | 1217 |
| 1 x 150 | 0,124 | 437 | 393 | 19,8 | 1440 | 1642 |
| 1 x 185 | 0,0991 | 507 | 445 | 21,7 | 1776 | 2009 |
| 1 x 240 | 0,0754 | 604 | 517 | 24,3 | 2304 | 2584 |
| 1 x 300 | 0,0601 | 697 | 583 | 26,7 | 2880 | 3207 |
| 1 x 400 | 0,0470 | 811 | 663 | 30,4 | 3840 | 4244 |
| 1 x 500 | 0,0366 | 940 | 749 | 33,6 | 4800 | 5280 |
| 1 x 630 | 0,0283 | 1083 | 843 | 37,5 | 6048 | 6636 |
| 1 x 800 | 0,0221 | 1228 | 935 | 41,7 | 7680 | 8377 |
| Nominal section [mm²] | Maximum resistance at 20 ℃ [Ω/km] | Air current capacity [A] | Earth current capacity [A] | Outer diameter (max.) [mm] | Metal mass [kg/km] | Cable weight (approx.)[kg/km] |
| 2 x 1,5 | 12,1 | 24 | 31 | 11,0 | 28,8 | 151 |
| 2 x 2,5 | 7,41 | 32 | 40 | 11,8 | 48,0 | 184 |
| 2 x 4 | 4,61 | 45 | 59 | 13,0 | 76,8 | 241 |
| 2 x 6 | 3,08 | 58 | 74 | 14,0 | 115,2 | 306 |
| 2 x 10 | 1,83 | 80 | 101 | 16,0 | 192,0 | 434 |
| 2 x 16 | 1,15 | 107 | 128 | 18,5 | 307,2 | 605 |
| 2 x 25 | 0,727 | 142 | 162 | 22,0 | 480,0 | 889 |
| 2 x 35 | 0,524 | 175 | 179 | 26,0 | 672,0 | 1168 |
| Nominal section [mm²] | Maximum resistance at 20 ℃ [Ω/km] | Air current capacity [A] | Earth current capacity [A] | Outer diameter (max.) [mm] | Metal weight [kg/km] | Cable weight (approx.)[kg/km] |
| 3 x 1,5 | 12,1 | 24 | 31 | 11,5 | 43,2 | 170 |
| 3 x 2,5 | 7,41 | 32 | 40 | 12,3 | 72,0 | 211 |
| 3 x 4 | 4,61 | 40 | 51 | 13,0 | 115,2 | 285 |
| 3 x 6 | 3,08 | 52 | 64 | 15,0 | 172,8 | 369 |
| 3 x 10 | 1,830 | 71 | 88 | 17,0 | 288,0 | 529 |
| 3 x 16 | 1,150 | 96 | 111 | 19,5 | 460,8 | 755 |
| 3 x 25 | 0,727 | 127 | 141 | 23,5 | 720,0 | 1122 |
| 3 x 35 | 0,524 | 157 | 170 | 26,0 | 1008,0 | 1490 |
| 3 x 50 | 0,387 | 190 | 204 | 29,5 | 1440,0 | 2049 |
| 3 x 70 | 0,268 | 242 | 252 | 34,0 | 2016,0 | 2808 |
| 3 x 95 | 0,193 | 293 | 302 | 38,5 | 2736,0 | 3704 |
| 3 x 120 | 0,153 | 339 | 345 | 42,5 | 3456,0 | 4627 |
| 3 x 150 | 0,124 | 390 | 386 | 47,5 | 4320,0 | 5770 |
| 3 x 185 | 0,0991 | 444 | 435 | 53,0 | 5328,0 | 7080 |
| 3 x 240 | 0,0754 | 522 | 504 | 59,5 | 6912,0 | 9080 |
| 3 x 300 | 0,0601 | 595 | 571 | 66,0 | 8640,0 | 11233 |
| Nominal section [mm²] | Maximum resistance at 20 ℃ [Ω/km] | Air current capacity [A] | Earth current capacity [A] | Outer diameter (max.) [mm] | Metal weight [kg/km] | Cable weight (approx.)[kg/km] |
| 4 x 1,5 | 12,1 | 24 | 31 | 12,2 | 57,6 | 192 |
| 4 x 2,5 | 7,41 | 32 | 40 | 13,1 | 96,0 | 241 |
| 4 x 4 | 4,61 | 40 | 46 | 14,0 | 153,6 | 333 |
| 4 x 6 | 3,08 | 52 | 58 | 16,0 | 230,4 | 436 |
| 4 x 10 | 1,830 | 71 | 79 | 18,5 | 384 | 636 |
| 4 x 16 | 1,150 | 96 | 100 | 21,0 | 614,4 | 921 |
| 4 x 25 | 0,727 | 127 | 141 | 25,5 | 960 | 1380 |
| 4 x 35 | 0,524 | 157 | 170 | 28,5 | 1344 | 1846 |
| 4 x 50 | 0,387 | 190 | 204 | 32,5 | 1920 | 2560 |
| 4 x 70 | 0,268 | 242 | 252 | 37,5 | 2688 | 3542 |
| 4 x 95 | 0,193 | 293 | 302 | 42,5 | 3648 | 4679 |
| 4 x 120 | 0,153 | 339 | 345 | 47,5 | 4608 | 5872 |
| 4 x 150 | 0,124 | 390 | 386 | 52,5 | 5760 | 7301 |
| 4 x 185 | 0,0991 | 444 | 435 | 59,0 | 7104 | 8988 |
| 4 x 240 | 0,0754 | 522 | 504 | 66,5 | 9216 | 11538 |
| 4 x 300 | 0,0601 | 595 | 571 | 73,5 | 11520 | 14288 |
THE 5 main advantages of R2V cable
- Reliability for fixed installations : R2V cable offers excellent mechanical strength and stable performance for fixed circuits in buildings and industrial installations.
- Durability and longevity : designed to withstand thermal stress and moderate environmental conditions, guaranteeing a long lifespan.
- Security : robust insulation reducing the risk of short circuit and fire, suitable for domestic and industrial electrical installations.
- Ease of implementation : ideal for installation in conduits, cable trays or fixed surfaces, simplifying installation and maintenance.
- Customizable solutions with ZMS Cable : possibility of custom R2V cables depending on length, the section and the specific needs of your projects.
Services & Delivery - ZMS Cable
- Personalized technical assistance : Expert advice for the choice of cable and tailor -made solutions.
- Certified products : Compliant with international standards (GB, IEC, BS, etc.). ISO certified 9001/14001, CE. Stable quality and rigorous controls before shipping.
- Adapted packaging : Wooden or cardboard coils with moisture protection, Possible personalized labeling.
- International delivery : Quick and reliable transport by sea, air or road, in more than 180 pays.
- Rapid shipping : Standard products in stock, Short deadlines for tailor -made cables.
- Reactive after-sales service : Complete follow -up after delivery, Technical assistance and replacement if necessary.
Similar products
- All Posts
- News
- Blog
- Electric cable types

Rapid responsiveness + Flexible customization, Reduction of project project costs with professional technical support in accordance with NFC/IEC standards..

Aluminum soul industrial cable, high temperatures resistant, flame, Anti-abrasion and anticorrosion, French standard ARVFV. Armor in strips....

ZMS Cable offers personalized AR2V cables. Suitable for your needs, They meet all your specific requirements. The cable....