Sy cable

Sy Flexible Control Cables
  • Applications : Ideal for controlling wiring, signaling and automation in industrial environments.
  • Benefits : High flexibility, Excellent mechanical protection thanks to the shielding in galvanized steel wires, Good resistance to oils and abrasion.
  • Structure : Flexible copper drivers, isolation PVC, shielding (GSWB), Transparent or personalized outdoor sheath.
  • ZMS customization : ZMS Cable offers custom SY cables - Dimensions, sheath colors, number of drivers, Special resistance to extreme conditions.

Product description

The SY cable is a flexible control cable with a galvanized steel protective braid, offering excellent mechanical resistance while maintaining good flexibility. It is widely used in industrial installations, Machine-tools, Control and automation systems, especially when the cable is subjected to moderate to high mechanical constraints.

This cable is distinguished by its transparent sheath which reveals the metal braid, which allows an easy visual inspection while strengthening its physical protection.

Construction

Component Description technique
Driver Multi-Brins naked copper drivers, class 5 according to IEC 60228 / From vde 0295, offering excellent flexibility.
Isolation PVC (polyvinyl chloride), heat resistant, in oil and abrasion.
Inner sheath PVC (polyvinyl chloride).
Shielding Braid in galvanized steel son (GSWB), ensuring optimal mechanical protection.
Outer sheath PVC transparent, facilitating the visual inspection of the cable state.
Sheath color Customizable according to customer needs (transparent, gris, noir, etc.).
Smoke and halogen -free materials can be used on request

SY cable applications

Industrial automation system : Used to connect control cabinets, sensors, actuators and other automation equipment.

Machine tools and production equipment : Adapted to electrical connections in high -frequency movements and vibrations.

CVC buildings and systems control : Control circuits for buildings automation and CVC systems.

Power and control circuits connections : Food systems, control and monitoring for fixed or light mobile installations.

Standard

IEC 60228 / VDE 0295; Bs one 50525-2-11;

Settings

Setting Value / Description
Tension nominale 300/500 V
Test voltage 3000 V
Service temperature Installation fixe : from -40 ° C to +70 ° C
Installation mobile : from -5 ° C to +70 ° C
Minimal curvature radius Installation fixe : 4 × cable Ø
Installation mobile : 15 × cable Ø
Isolation resistance > 20 MΩ·km
Flame resistance Compliant with IEC standard 60332-3
Driver identification Black drivers with white numbering
From 3 drivers : Green/yellow earth thread

Technical data

Number of drivers Conductor Section (mm²) Nominal external diameter(mm) Quantity of copper (indicative)(kg/km) Weight(kg/km)
2 0.5 7.8 10 87
3 0.5 8.1 15 95
4 0.5 8.5 19.2 107
5 0.5 9.2 24 123
7 0.5 9.7 33.6 147
10 0.5 11.6 48 196
12 0.5 11.9 58 213
14 0.5 12.5 67 237
18 0.5 13.9 86.4 291
21 0.5 14.9 101 332
25 0.5 15.6 120 375
30 0.5 16.5 144 475
40 0.5 18.8 192 545
61 0.5 21.9 293 773
2 0.75 8.2 14.4 97
3 0.75 8.5 21.6 108
4 0.75 9.2 28.8 126
5 0.75 9.7 36 146
7 0.75 10.3 50 172
9 0.75 12.4 65 224
12 0.75 12.9 86 260
15 0.75 14.1 108 315
18 0.75 14.9 130 355
25 0.75 17 180 465
34 0.75 19.3 245 596
50 0.75 22.8 360 832
2 1 8.5 19.2 106
3 1 8.8 28.8 119
4 1 9.5 38.4 141
5 1 10.1 48 164
7 1 11 67 200
8 1 12.5 77 234
9 1 13.2 86 260
12 1 13.9 115 309
14 1 14.4 134 345
18 1 15.9 173 415
20 1 16.8 192 455
25 1 18.1 240 548
34 1 20.5 326 714
41 1 22.2 394 832
50 1 24.2 480 987
2 1.5 9.3 29 117
3 1.5 9.7 43 151
4 1.5 10.2 58 173
5 1.5 11.1 72 202
7 1.5 11.9 101 248
8 1.5 14 115 320
12 1.5 15.4 173 396
14 1.5 15.9 202 438
18 1.5 17.6 259 580
25 1.5 20.3 360 713
32 1.5 22.1 461 876
50 1.5 27.1 720 1305
3 2.5 11.1 72 206
4 2.5 12.1 96 249
5 2.5 13.2 120 295
7 2.5 14.3 168 373
12 2.5 18.2 288 586
18 2.5 21.4 432 823
25 2.5 24.4 600 1093
3 4 12.7 115 285
4 4 14 154 348
5 4 15.1 192 410
7 4 16.4 269 519
4 6 16.2 230 482
5 6 17.7 288 579
7 6 19.2 403 740
4 10 17.4 384 731
5 10 21.5 480 889
7 10 23.4 672 1146
4 16 22.4 614 1384
5 16 24.6 768 1740
4 25 26.9 960 1680
5 25 30 1,200 2050
4 35 30.2 1,344 2170

ZMS cable personalization service - Sy cable

Customizable option Details
Driver section Of 0,5 mm² à 95 mm²
Number of drivers Of 2 Multiconductor structures conductors
Sheath color Transparent, gray, noire, or according to customer preferences
Specific requirements – Materials without halogen with low smoke (LSZH)
– Reinforced mechanical protection
– Increased resistance to oils and chemicals

Comparison of SY cables, CY et YY

Features Sy cable CY cable YY cable
Shielding / Protection Galvanized steel braid (mechanical protection) Tinned copper braid (protection EMI / CEM) No shielding or mechanical protection
Mechanical resistance High Average Weak
Protection against interference Average (partial protection) High (against electromagnetic interference) None
Flexibility Good Good Very good
Typical application Industrial environments subject to efforts Systems sensitive to electromagnetic disturbances Standard interior installations
Utilisation mobile Oui Oui Oui
Outer sheath PVC transparent PVC PVC
Tension nominale 300/500 V 300/500 V 300/500 V
Prix AVERAGE Pupil Economic

Sy cable advantages

Strong resistance to mechanical stresses : The shielding structure braided in galvanized steel wire has excellent shock and abrasion resistance.

Low signal interference : The shielding structure effectively reduces electromagnetic interference and ensures stable signal transmission.

Good flexibility and easy installation : Suitable for scenes with flexions or frequent movements, Flexible and practical installation.

A variety of specifications, Personalization management : ZMS Cable offers a variety of sizes and sheath materials to meet the needs of different projects and support personalized personalization services.

High sustainability : It has good resistance to oil and chemical corrosion and can adapt to difficult industrial environments.

FAQ - Frequent questions about the SY cable

1. SY cable can be used outdoors ?
The SY cable is provided for indoor use. For the outside, You must use a version with UV resistant sheath or opt for a specific armored outdoor cable.

2. What is the maximum temperature supported by the SY cable ?
Installation fixe : up to +80 ° C
Installation mobile : up to +70 ° C

3. SY cable is available in custom version at ZMS ?
Oui, ZMS Cable offers personalized manufacturing of Sy cable : number of drivers, sections (mm²), Specific lengths, color codes, Gaine printing, etc.

4. What is the lifespan of the Sy cable ?
An usage normal, The lifespan exceeds 15 years thanks to the quality of materials and rigorous production control at ZMS.

    Request a free quote, we will respond to you within 24 hours.

    Your Email*:

    Your Name*:

    Your Country:

    Your Phone*:

    Your message*: