NHXH and NHXCH cables

  • Halogen-free power cables, fire -resistant (FE180/E30, FE180/E90), U0/U 0,6/1 kV, copper conductors – suitable for fixed security installations.
  • Special halogen-free insulation and sheathing : low smoke and toxic gas emissions to protect people and sensitive equipment.
  • Excellent fire resistance : maintaining the integrity of the insulation and electrical operation during 30 has 90 minutes depending on configuration.
  • Compliant with IEC standards 60331, IN 50200
  • Available in armored version (Socialist Republic of Vietnam) with concentric conductor for electromagnetic protection and improved grounding.
  • Custom manufacturing by ZMS CABLE : sections, lengths and packaging adapted to your needs.

Get a Quote

What is NHXH cable and NHXCH cable ?

NHXH and NHXCH cables are halogen-free power and control cables, specially designed to guarantee the safety of electrical installations in the event of fire. Complies with European standards and classification FE180/E30-E90, they ensure, even during a fire, integrity of insulation and maintenance of function for a defined period of time.
NHXH cable is the standard version, unshielded, ideal for electrical networks in public buildings, Hospitals, train stations or industrial sites. The NHXCH cable, as for him, incorporates copper shielding for effective protection against electromagnetic interference, making it ideally suited to sensitive environments such as data centers or industrial control systems.

Construction

Features NHXH cable – FE180/E30 NHXH cable – FE180/E90 NHXCH cable – FE180/E30 NHXCH cable – FE180/E90
Tension nominale 0,6/1 kV
Driver Copper class 1 (< 25 mm²) Copper class 2 (≥ 25 mm²)
Isolation Halogen-free polymer with flame-resistant mica tape
Internal sheath Halogen-free compound
Concentric conductor Concentric copper wires with helical copper tape
Outer sheath Halogen-free polymer

Application of NHXH cables & Socialist Republic of Vietnam

  • Fire safety installations (automatic detection and extinguishing systems)
  • Emergency lighting and power supply for emergency exits
  • Fire alarm and emergency communications systems
  • Elevators and emergency ventilation guaranteeing safe evacuation
  • Sensitive public environments : hospitals, schools, stations, airports
  • Tunnels and transport infrastructures requiring reliable power even in the event of a disaster

Standard

NHXH and NHXCH – FE180 – E30 / E90
Flame retardantVDE 0482-266-2-4 / IEC 60332-3-24
Smoke densityYOUR ONE 61034 / IEC 61034
Halogen-freeYOUR ONE 50267 / IEC 60754
Fire resistant insulationFE 180 (Compliant with IEC 60331)
FE 180 : integrity of the insulation guaranteed during 180 minutes in direct contact with flames
Circuit integrityAvailable in E30 / E90
– E30 : guarantees the operation of electrical circuits for at least 30 minutes during a fire.
– E90 : guarantees operation for at least 90 minutes, ideal for critical systems (fire pumps, emergency ventilation).

Technical parameters of NHXH and NHXCH cables (0,6/1 kV)

Tension nominale0,6/1 kV
Test voltage4 kV (AC)
Installation temperature–5°C to +50 °C
Operating temperature–35°C to +90 °C
Short-circuit temperature (max.)Until 250 °C
Minimum bending radius. (fixed)Monoconductor : 15ר
Multiconductor : 12ר

Technical data

IN 60332-3-24 NHXH FE180-E90 0.6/1kV Cable

Number of drivers Nominal section (mm²) Driver type Nominal external diameter (mm) Poids nominal (kg/km)
1 16 RM 10.5 250
1 25 RM 12.5 355
1 35 RM 13.5 460
1 50 RM 15 596
1 70 RM 16.5 810
1 95 RM 19 1100
1 120 RM 20.5 1350
1 150 RM 22.5 1650
1 185 RM 25 2050
1 240 RM 28 2650
1 300 RM 31 3275
2 1.5 RE 14.3 275
2 2.5 RE 14.9 320
3 1.5 RE 15 315
3 2.5 RE 15.9 371
3 4 RE 16.7 435
3 6 RE 17.8 526
3 10 RE 19.5 691
3 16 RM 22.3 982
3 25 RM 25.8 1392
3 35 RM 28.4 1778
3 35/16 RM 29.5 1964
3 50/25 RM 33.6 2633
3 70/35 RM 38.1 3563
3 95/50 RM 43.4 4768
3 120/70 RM 46.9 5856
4 1.5 RE 16.1 365
4 2.5 RE 17 429
4 4 RE 18 515
4 6 RE 19.2 628
4 10 RE 21.1 839
4 16 RE 24.3 1210
4 25 RM 28.1 1717
4 35 RM 31 2209
4 50 RM 35.1 2921
4 70 RM 40 3980
4 95 RM 45.2 5321
4 120 RM 49 6475
4 150 RM 53 7725
5 1.5 RE 17.4 429
5 2.5 RE 18.4 506
5 4 RE 19.5 612
5 6 RE 20.9 752
5 10 RE 23 1009
5 16 RM 26.6 1465
5 25 RM 30.9 2105
5 35 RM 36 2500

IN 60332-3-24 NHXH FE180-E30 0.6/1kV Cable

Number of driversNominal section (mm²)Driver typeNominal external diameter (mm)Poids nominal (kg/km)
116RM18.6207
125RM20.6307
135RM22.8407
150RM26.3535
170RM30744
195RM10.21009
1120RM18.61248
1150RM20.61538
1185RM22.81917
1240RM26.32521
1300RM303400
21.5RE10.2145
22.5RE11180
24RE11.8224
26RE12.8282
210RE14.4393
216RM17.3605
31.5RM10.6165
32.5RM11.5209
34RM12.4268
36RM13.5344
310RM15.6506
316RM18761
325RM22.31160
335RM24.91522
350RM27.7198
370RM322746
395RM36.53712
325/16RM23.41335
335/16RM25.71683
350/25RM292244
370/35RM33.43101
395/50RM38.34207
3120/70RM42.65315
41.5RE11.3192
42.5RE12.3249
44RE13.3322
46RE14.5418
410RE16.8620
416RM19.8944
425RM24.31452
435RM27.11906
450RM30.52514
470RM35.33497
495RM40.24728
4120RM44.55882
4150RM497199

IN 60332-3-24 NHXCH FE180-E90 0.6/1kV Cable

Number of drivers Nominal section (mm²) Driver type Concentric conductor diameter (mm) Nominal external diameter (mm) Poids nominal (kg/km)
2 1.5 RE 1.5 16 300
2 2.5 RE 2.5 17 350
3 1.5 RE 1.5 16.8 363
3 2.5 RE 2.5 17.9 434
3 4 RE 4 19 434
3 6 RE 6 21 434
3 10 RE 10 24.1 949
3 16 RE 16 27.3 1340
3 25 RM 16 30.7 1766
3 35 RM 16 33.3 2172
3 50 RM 25 37.4 2857
3 70 RM 35 42.5 3839
3 95 RM 50 47.8 5082
3 120 RM 70 51.4 6204
3 150 RM 70 55.7 7340
3 185 RM 95 61.7 9142
3 240 RM 120 67.9 11582
4 1.5 RE 1.5 18 450
4 2.5 RE 2.5 19.2 505
4 4 RE 4 20.3 608
4 6 RE 6 22.5 777
4 10 RE 10 26.4 1153
4 16 RM 16 29.3 1584
4 25 RM 16 33.1 2120
4 35 RM 16 36 2634
4 50 RM 25 41.1 3524
4 70 RM 35 46.2 4695
4 95 RM 50 52 6242
4 120 RM 70 56 7622
4 150 RM 70 61 9096
4 185 RM 95 67.5 11307
4 240 RM 120 74.4 14359
7 1.5 RE 2.5 20.9 588
7 2.5 RE 2.5 22.1 696
12 1.5 RE 2.5 26.2 620
12 2.5 RE 2.5 28.2 1168
24 1.5 RE 6 37.6 1979
24 2.5 RE 2.5 41 2465

IN 60332-3-24 NHXCH FE180-E30 0.6/1kV Cable

Number of driversNominal section (mm²)Driver typeConcentric conductor diameter (mm)Nominal external diameter (mm)Poids nominal (kg/km)
21.5RE1.510.8133
22.5RE2.512171
31.5RE1.511.2166
32.5RE2.512.5219
34RE413.4291
36RE615.3393
310RE1017576
316RE1619.6860
325RM16231194
335RM1625.61521
350RM2528.82037
370RM3533.72841
395RM5038.2384
3120RM7042.34869
3150RM7046.65844
3185RM9552.37400
3240RM12059.79661
41.5RE1.511.9192
42.5RE2.513.3254
44RE414.3341
46RE616.3471
410RE1018.2685
416RM1621.11035
425RM16251465
435RM1627.81886
450RM2531.62539
470RM35373556
495RM5041.94816
4120RM7046.66101
4150RM7051.17323
4185RM9557.69285
4240RM12065.812141
52.5RE2.514.3283
56RE617.5530
71.5RE2.514.2274
72.5RE2.515.4348
121.5RE2.517.4399
122.5RE419.2556
241.5RE623.7744
242.5RE1026.11027
301.5RE624.8873
302.5RE1027.41216

Advantages of NHXH cables & Socialist Republic of Vietnam

  • Fire resistant : Certification FE180/E30 et FE180/E90, guaranteeing the maintenance of the electrical function during 30 has 90 minutes in case of fire.
  • Halogen-free and low smoke : Limitation of toxic and corrosive gases to protect sensitive people and equipment.
  • Increased security : Risk reduction in emergencies, ensuring the continuity of critical systems.
  • Compliance with European standards : Manufactured according to IEC 60331 and in 50200, guarantee of quality and reliability.
  • Adapted to demanding environments : Suitable for both public infrastructures and industrial sites with a high level of security.
  • Tailor-made solutions : ZMS CABLE offers custom design and manufacturing of NHXH and NHXCH cables to your specific needs

Services & Delivery at ZMS Cable

  • Personalized manufacturing service (OEM / ODM) : Custom cable design and production according to your technical specifications, with customization of the marking, Colors and packaging.
  • Rapid global logistics : Shipping shipping, terrestrial or air to more than 120 pays ; Flexible delivery according to your deadlines.
  • Certified quality : All products are tested before shipping ; conformity this / IEC / ISO ; test reports provided on request.
  • Neat and customizable packaging : ZMS cables are packaged on wooden coils, wavy boxes or drums, with hermetically sealed ends for moisture protection. Outdoor marking can be printed on request with waterproof materials.
  • Dedicated technical support : Our engineers and advisers accompany you in the choice of the electric cable most suited to your installations, in accordance with local standards.

    Request a free quote, we will respond to you within 24 hours.

    Your Name*:

    Your Email*:

    Your Phone*:

    Your Country:

    Your message*: