NYM cable

  • Configuration flexible : two versions, ONE (with earth) et nym-o.
  • Resistance to wear and corrosion : PVC double sheath, acid resistant, to alcalis and oils.
  • Large temperature range : From -30 ° C to +70 ° C, cold installation and high temperature stability.
  • High conductivity : Solid or stranded copper conductors (class 1/2), some tin-plated for better corrosion resistance.
  • Certifications multiples : CE/VDE/TÜV conformity to European standards, flame retardant and low smoke and halogen emissions.
  • Decreasing rates : Minimum command of 300 m, volume discounts, customization of the sheath and number of conductors.

Product description

The cable Nym is a fixed wiring cable widely used in European buildings, with PVC insulation and jacket and twisted solid copper conductor (Class 1 or 2). It is available in two models : ONE (with yellow-green grounding identification) et NYM-O (without earthing identification). NYM cable is available in single-pole or multi-pole configurations, with a nominal voltage of 300/500V, suitable for residential electrical distribution systems, commercial and industrial. It can be buried directly in concrete or installed in conduits, cable trays or inside walls. Its maximum operating temperature is +70°C, while the installation temperature can drop to -35°C, avoiding direct exposure to the sun.

Construction

ComponentsMaterials and specifications
DriverCopper receipt (Solid Copper Class 1 ou toronné Classe 2), range of sections : 1,5~10 mm²
IsolationPVC (thickness conforms to IEC standard 60227, For example, for a driver 1,5 mm², insulation thickness ≥ 0,7 mm)
FillingFalfa -free fire -free polypropylene rope (filling rate ≥ 85 %)
Earth conductorTwo-tone yellow-green PVC insulated copper conductor (section ≤ 50 % of the main driver)
SheathPVC (Thickness ≥ 1,2 mm, Complies with the standard in 50363-3)
ZMS Cable offers customization of NYM cables according to your material requirements, standards and colors.

Applications of NYM cable

  • Electrical distribution in buildings : Widely used for fixed wiring in residential buildings, commercial and industrial, such as lighting circuits, socket lines and power supply of electrical equipment.
  • Installation in concrete : Can be directly embedded in static concrete or masonry structures, but should be avoided in concrete environments subject to vibration.
  • Indoor and outdoor installation : Suitable for installation in conduits, cable trays or inside walls, with UV protection required for outdoor installations.
  • Low voltage power transmission : Tension nominale de 300/500V, compatible with low voltage distribution systems and powering small motors and appliances.
  • Multi-environment compatibility : Suitable for dry and humid environments, meeting the needs of electrical control and signal transmission.

Standard

From vde 0281-1, A 21031-4 and HD 21.4S2 and IEC 60227-4

Properties

Settings Typical values / Beach
Tension nominale 300/500 V
Test voltage 2000 V C.A.
Driver resistance (20°C) ≤12,1 Ω/km (1,5 mm²) ~ ≤1.83 Ω/km (10 mm²)
Isolation resistance ≥0,011 TΩ·km (70°C)
Continuous operating temperature -30° C to +70 ° C
Maximum temperature 70°C
Short circuit temperature +160°C (5 seconds)
Radius of curvature 6 × cable diameter (installation fixe)
Tensile strength ≥15 N/mm² (sheath)
Flame delay classification Complies with IEC standards 60332-1-2, One 60332-1-2 and in 60332-1-2

Technical data

Section (mm²) Resistance to 20℃(Ω/km) Outdoor diameter (mm) Weight(kg/km)
1 x 1,5 12,1 5,3 45
1 x 2,5 7,41 5,8 58
1 x 4 4,61 6,5 80
1 x 6 3,08 7,05 104
1 x 16 1,15 9,25 211
1 x 25 0,727 10,95 317
1 x 35 0,524 12 414
2 x 1,5 12,1 8,2 107
2 x 2,5 7,41 9,5 150
2 x 4 4,61 11,2 218
2 x 6 3,08 12,3 281
2 x 16 1,15 17,1 591
2 x 35 0,524 22,6 1140
3 x 1,5 12,1 8,5 123
3 x 2,5 7,41 9,95 176
3 x 4 4,61 11,8 261
3 x 6 3,08 13 343
3 x 16 1,15 18,1 735
3 x 25 0,727 22,2 1135
3 x 35 0,524 24,45 1472
4 x 1,5 12,1 9,8 162
4 x 2,5 7,41 11,05 221
4 x 4 4,61 13,7 346
4 x 6 3,08 14,7 440
4 x 16 1,15 19,8 916
4 x 25 0,727 24,3 1418
4 x 35 0,524 26,85 1852
5 x 1,5 12,1 10,6 195
5 x 2,5 7,41 11,95 269
5 x 4 4,61 14,2 392
5 x 6 3,08 15,7 521
5 x 16 1,15 22,05 1132
5 x 25 0,727 26,65 1740
5 x 35 0,524 30,4 2338
7 x 1.5 12,1 12,5 272
7 x 2.5 7,41 12,8 325

Comparison between NYM-J cable and NYM-O cable

Comparison criteriaONENYM-O
Grounding DesignWith independent yellow-green earth conductor (same section)Without earth conductor
Voltage level300/500 V (three-phase system)300/300 V (single phase system)
Sheath performanceDouble layer gray PVC jacket (better UV resistance)Single-layer orange PVC sheath (lower UV resistance)
Fill layerPresent (reinforces mechanical protection)Absent
Current carrying capacityHigher (16,5 A vs 14,0 A)Weaker
Environmental adaptabilityBetter resistance to corrosion and humiditySuitable for dry or temporary environments
Certification requirementsMust meet grounding system standards (IEC 60364)Suitable for ungrounded installations

Selection recommendations(NYM-J cable or NYM-O cable)

When to choose NYM-J cable ?

  • Fixed installation requiring earthing protection (ex. : residential and commercial buildings)
  • Three-phase electrical distribution systems (tension > 300V)
  • Humid or corrosive environments (ex. : industrial workshops)

When to choose NYM-O cable ?

  • Single-phase low-voltage control circuits (ex. : lighting, signal transmission)
  • Power supply of temporary or mobile equipment (use with isolation transformer)
  • Limited budget projects (cost reduction)

NYM Cable vs Similar Cables

Features Nym H07RN-F (rubber cable) Sihf (high temperature silicone cable) XLPE-insulated
Standards IEC 60227 IEC 60245 IEC 60684 IEC 60502-1
Conductor material Copper (Class 1/2) Copper (Class 5) Tinned copper (Class 2) Copper (Class 1/2)
Insulation material PVC EPR rubber Silicone Cross-linked polyethylene (XLPE)
Sheath material PVC Chloroprene rubber Fiberglass + silicone PVC or LSZH
Temperature range -30° C to +70 ° C -40°C to +90°C -60°C to +180°C -40°C to +90°C
Flame resistance Compliant with IEC 60332-1-2 Compliant with IEC 60332-1-2 Compliant with IEC 60332-3-22 (flame propagation on bundled cables) Compliant with IEC 60332-3-22
Oil resistance Weak (PVC swelling) Excellent (test ONE 60811-404) Excellent Good (moderate resistance of XLPE to oils)
Typical applications Fixed wiring inside buildings Mobile equipment / temporary food High temperature industrial equipment Electrical distribution systems

Benefits

  • High durability structure : PVC insulation and sheath provide excellent wear resistance, with acids, to bases and chemical corrosion, suitable for dry environments, wet and concrete.
  • Large temperature range : Operating temperature range -35°C to +70°C, allowing installation at low temperatures and stable operation at high temperatures, meeting the demands of extreme environments.
  • Excellent driver performance : Twisted Solid Copper Conductor (Class 1/2), high purity copper core ensuring low resistance and high conductivity, some models having a tinned conductor to improve corrosion resistance.
  • Multiple security certifications : Complies with European VDE standards, CE, with fire resistant properties and electrical insulation reliability, meeting building safety standards.
  • Versatile and flexible applications : Available in monopolar configurations 12 drivers, covering energy transmission needs, lighting and power equipment for residential buildings, commercial and industrial.
  • Personalized service : ZMS CABLE offers a service of tailor -made cables, including conductor specification, the number of drivers, the color of the sheath (For example, gray RAL7001 or black RAL9005) and specific weather resistance needs.

    Request a free quote, we will respond to you within 24 hours.

    Your Name*:

    Your Email*:

    Your Phone*:

    Your Country:

    Your message*: