- NYA cable, durable and corrosion resistant, adapted to various environments.
- Industrial and domestic applications, electricity transmission solutions.
- ZMS Cable offers tailor -made cable services depending on the materials and specifications of your requirements.
Product description
The NYA cable is an electric cable with rigid copper driver with PVC insulation, Complies with IEC standards. It is widely used for fixed electrical installations inside the buildings. Thanks to its simple structure and its low cost, Lighting is perfectly suitable for wiring, distribution tables and electrical boxes. NYA cable is intended for dry environments and constitutes a basic solution in electrical installations.
Construction
Driver | Copper receipt, class 1 or 2 (According to IEC standard 60228) |
Number of drivers | 1 (single conductor) |
Isolation | PVC (Vinyl polychloride), Compliant with IEC standard 60502 |
NYA cable applications
- Interior electric wiring in houses, Offices and commercial buildings ( lighting, electrical outlet etc. )
- Connection of electrical tables, Distribution boxes and devices
- Use in cable paths, Logs and sheaths
- Ideal for projects requiring an isolated rigid copper cable PVC 500V
That represent the letters of the NYA cable ?
Nya cable means :
N : Copper driver
Y : Isolation external EN PVC
A : Unique copper driver cable (Copper cables included in a single set of cables)
Standard
IEC, BS, IEC 60227, VDE 0281, BS 6004, NF C 32-201
Settings
Element | Description |
Tension nominale | 450/750 V |
Service temperature | -5° C to +70 ° C (fixe) / up to +160 ° C in short circuit (max. 5 seconds) |
Min curvature radius. | 4 × exterior diameter of the cable |
Flame resistance | Compliant with IEC standard 60332-1 |
Colors available | Rouge, bleu, green/yellow, noir, marron, gris |
Utilisation | Fixed interior installations, Electric Tables, lighting, sockets, etc. |
Manufacturing standards | IEC 60227, VDE 0281, BS 6004, NF C 32-201 |
Colors available | Noir, Bleu, Marron, Rouge, Yellow/green (terre), Gris, Orange (on demand) |
Section beach | Of 0.5 mm² à 16 mm² (Other sections on special request) |
Packaging | Rollers 100 m / Coils / Personalized cut according to your needs |
Personalization service | ZMS Cable offers tailor -made cables Depending on your materials, colors, lengths, and required standards |
Available certifications | CE, RoHS, ISO 9001, IEC 60227, VDE, Others on request |
Applications types | Residential, industrial, Electric Tables, sockets, lighting, etc. |
Technical data
Nominal section (mm²) | Driver diameter (mm) | Insulation thickness (mm) | Outside diameter Approx. (mm) | Max resistance. at 20 ° C (Ω/km) | Poids approx. (kg/km) |
0.5 | 0.9 | 0.6 | 2.1 | 39 | 7.2 |
0.75 | 1 | 0.6 | 2.3 | 26 | 10.8 |
1 | 1.1 | 0.6 | 2.4 | 19.5 | 14.4 |
1.5 | 1.4 | 0.7 | 2.8 | 13.3 | 21.6 |
2.5 | 1.8 | 0.8 | 3.5 | 7.98 | 35 |
4 | 2.25 | 0.8 | 3.9 | 4.95 | 51 |
6 | 2.8 | 0.8 | 4.5 | 3.3 | 73 |
10 | 3.6 | 1 | 5.9 | 1.91 | 123 |
16 | 4.5 | 1 | 6.9 | 1.21 | 186 |
Comparaison entre le câble NYA et d'autres types de câbles
Comparison of NYA cables, Nym et nyy
Features | NYA cable | NYM cable | Câble Nyy |
Structure | 1 Rigid copper driver | 2 has 5 Rigid copper drivers | 2 has 5 Rigid copper drivers |
Isolation principale | PVC simple | Double isolation PVC (core + PVC external sheath) | Reinforced PVC (isolation + robust sheath) |
Tension nominale | 300/500 V | 450/750 V | 300/500 V | 0,6/1 kV |
Mechanical protection | Weak - requires pvc or chute conduit | Average - more resistant insulation | High - Robust outdoor sheath |
Waterproofing / humidity | Non -resistant humidity | Resist with ambient humidity | Resist with humidity, Usable in wetlands |
Buried pose | Not recommended | Not recommended | Recommended for buried installation |
Outdoor | With protection only | In dry zone (with if exposed protection) | Without protection |
Inside | Oui (With PVC sheath) | Oui | Oui |
Flexibility | Weak (rigid soul) | Average (rigid multiconductors) | Average |
Typical use | Interior fixed installations in conduits | Domestic and tertiary wiring, dry areas | Industrial facilities, buried or wet |
Remarks | Requires sheath or driver for safety | More secure than NYA, but limited inside | Versatile and robust, the most reliable of the three |
Differences between NYA and NYAF cables
Features | NYA cable | Nyaf cable |
Driver structure | Rigid copper monoconductor | Flexible multi -copper driver |
Flexibility | Weak (rigid) | High (flexible, very flexible) |
Section beach | 0,5 mm² à 400 mm² | 0,5 mm² à 500 mm² |
Isolation | PVC | Thermoplastic PVC |
Maximum temperature (court-circuit) | Up to 160 ° C | Up to 70 ° C in normal use |
Recommended use | Installations fixes, under plaster, canalisations PVC, electrical panels | Control circuits, panels, mobile devices, wetlands |
Outdoor | Not recommended | Possible with adequate protection |
Typical application area | Residences, workshops, tableaux, lighting | Sous-sols, parking lots, Mobile and flexible applications |
Humidity | Recommended dry areas | Suitable for wetlands with appropriate conduits or fixations |
Main advantage | Good sustainability, transmission stable, low cost | Great flexibility, Ideal for mobile or complex connections |
Inconvenience | Not very flexible, Limited use in high mobility places | Less used in traditional fixed installations |
Advantages of the NYA cable
- Rigid copper electric cable in accordance with IEC standards : Performance and security guaranteed.
- Isolation a PVC Robuste : Ideal for dry environment facilities.
- Economical solution : The NYA cable is a cheap electric cable for standard fixed installations.
- Availability in stock and tailor -made : ZMS CABLE, tailor -made nya cable supplier, offers personalized cables according to your needs : sections, colors, packaging, as well as different insulation materials to choose from (PVC NYA cable, an XLPE, you are a CPE).
- High compatibility : Perfectly suitable for residential wiring, tertiary and industrial.