- Na2xy cable – rigid aluminum cable, Isolated XLPE, gaine PVC, tension nominale 0,6/1 kV.
- Excellent electrical conductivity and stable performance for low voltage networks.
- Heat resistant XLPE insulation, mechanical constraints and harsh environments.
- Robust PVC jacket offering good protection against humidity and chemicals.
- Easy installation in industrial networks, residential and public infrastructure.
- Economical solution compared to copper cables, while ensuring safety.
- Compliant with international standards, suitable for projects in Europe, Africa and French-speaking markets.
- Long life and proven reliability, ideal for large-scale electrical projects.
Product description
NA2XY cable is a low voltage electrical distribution cable (0,6/1 kV) fitted with a rigid aluminum conductor, XLPE insulation and a resistant PVC sheath. Thanks to its robust design, it provides excellent reliability and long life in industrial installations, residential and public infrastructure. NA2XY cables power distribution cables are a lightweight alternatives to N2XY cables thanks to their aluminium conductors, making it an economical and efficient solution for large-scale electricity projects. Compliant with international standards, the NA2XY cable is particularly appreciated in the French-speaking European and African markets for its security, its ease of installation and its excellent quality-price ratio.
NA2XY Cable Construction
| NA2XY 0.6/1kV | NA2XY 1.8/3kV | |
| Tension nominale | 0,6/1 (1,2) kV AC / 0,9/1,8 kV DC | 1,8/3 (3,6) kV AC / 2,7/5,4 kV DC |
| Standards | IEC 60502-1, VDE 0276-603 | IEC 60502-1 |
| Driver | Wired aluminum, Class 2 (Class 1 on demand) | Wired aluminum, Class 2 compacted |
| Isolation | XLPE (Crosslinked Polyethylene) | XLPE (Crosslinked Polyethylene) |
| Outer sheath | PVC (Customizable color) | PVC |
NA2XY Cable Applications
NA2XY cable is mainly used in the following areas :
- Powering residential and commercial buildings
- Public lighting networks and urban infrastructure
- Industrial facilities and production sites
- Distribution substations and low-voltage electrical networks
- Underground installation in trenches or conduits
- Outdoor, outdoors or in water
Standard
HD 603 S1, IEC 60502-1, VDE 0276-603
NA2XY cable parameters
| Features | NA2XY 0.6/1kV | NA2XY 1.8/3kV |
| Service temperature | -35° C to +70 ° C (installed fixed) | Up to +90°C in service, +250°C en court-circuit |
| Min curvature radius. | 12–15 × outer Ø (depending on the number of drivers) | 15 × external Ø |
| Typical applications | Low voltage distribution networks, buildings, public infrastructure | Electrical networks requiring higher voltage, demanding industrial applications |
| Key Benefits | Light, economic, suitable for common installations | Reinforced thermal and electrical resistance, higher load capacity |
Technical data of the NA2XY cable
NA2XY 0.6/1kV
| Number of drivers | Section nominal (mm²) | Nominal thickness of insulation (mm) | Nominal sheath thickness (mm) | Nominal external diameter (mm) | Poids nominal (kg/km) | |
| Phase driver | Earth conductor | |||||
| 1 | 95 | – | 1.1 | 1.5 | 16.1 | 390 |
| 1 | 120 | – | 1.2 | 1.5 | 17.7 | 465 |
| 1 | 150 | – | 1.4 | 1.6 | 20.3 | 580 |
| 1 | 185 | – | 1.6 | 1.6 | 21.6 | 715 |
| 1 | 240 | – | 1.7 | 1.7 | 24.4 | 905 |
| 1 | 300 | – | 1.8 | 1.8 | 27.2 | 1120 |
| 1 | 400 | – | 2 | 1.9 | 30.3 | 1440 |
| 1 | 500 | – | 2.2 | 2 | 33.9 | 1770 |
| 1 | 630 | – | 2.4 | 2.2 | 38.6 | 2180 |
| 3 | 70 | 35 | 1.1 | 1.9 | 25.9 | 1450 |
| 3 | 95 | 50 | 1.1 | 20 | 29.2 | 1910 |
| 3 | 120 | 70 | 1.2 | 2.1 | 32.4 | 2410 |
| 3 | 150 | 70 | 1.4 | 2.3 | 35.5 | 3535 |
| 3 | 185 | 95 | 1.6 | 2.4 | 39.5 | 3810 |
| 3 | 240 | 120 | 1.7 | 2.6 | 44.6 | 4880 |
| 3 | 300 | 150 | 1.8 | 2.8 | 49.5 | 5610 |
| 4 | 16 | 16 | 0.9 | 1.8 | 20.4 | 675 |
| 4 | 25 | 16 | 0.9 | 1.8 | 22.4 | 910 |
| 4 | 35 | 16 | 0.9 | 1.8 | 26 | 1120 |
| 4 | 50 | 25 | 1 | 1.9 | 28.7 | 1475 |
| 4 | 70 | 35 | 1.1 | 2 | 30.7 | 1985 |
| 4 | 95 | 50 | 1.1 | 2.1 | 32.7 | 2580 |
| 4 | 120 | 70 | 1.2 | 2.3 | 36.8 | 3175 |
| 4 | 150 | 70 | 1.4 | 2.4 | 41.3 | 4035 |
| 4 | 185 | 95 | 1.6 | 2.6 | 46.3 | 4945 |
| 4 | 240 | 120 | 1.7 | 2.8 | 52.1 | 6425 |
| 4 | 300 | 150 | 1.8 | 3 | 57.7 | 7910 |
NA2XY 1.8/3kV
| Number of drivers | Nominal section (mm²) | Nominal external diameter (mm) | Poids nominal (kg/km) |
| 1 | 16 | 10.9 | 140 |
| 1 | 25 | 12 | 180 |
| 1 | 35 | 13.1 | 215 |
| 1 | 50 | 14.4 | 265 |
| 1 | 70 | 16.2 | 350 |
| 1 | 95 | 17.7 | 430 |
| 1 | 120 | 19.3 | 530 |
| 1 | 150 | 21.5 | 635 |
| 1 | 185 | 22.6 | 750 |
| 1 | 240 | 25.2 | 935 |
| 1 | 300 | 27.5 | 1125 |
| 1 | 400 | 30.4 | 1410 |
| 1 | 500 | 34.3 | 1775 |
| 1 | 630 | 38.4 | 2280 |
| 1 | 800 | 43.8 | 2945 |
| 1 | 1000 | 50.7 | 3710 |
| Nominal section (mm²) | Maximum continuous conductor resistance at 20°C (Ω/km) | Maximum alternating resistance of the conductor at 50 Hz (Ω/km) | Rated current (A) | ||
| Laying in the ground | Conduit installation | Installation in the open air | |||
| 16 | 1.91 | 2.435 | 102 | 74 | 85 |
| 25 | 1.2 | 1.53 | 131 | 96 | 112 |
| 35 | 0.868 | 1.107 | 157 | 115 | 137 |
| 50 | 0.641 | 0.817 | 185 | 137 | 166 |
| 70 | 0.443 | 0.565 | 227 | 170 | 210 |
| 95 | 0.32 | 0.408 | 271 | 205 | 257 |
| 120 | 0.253 | 0.323 | 309 | 236 | 300 |
| 150 | 0.206 | 0.263 | 346 | 267 | 343 |
| 185 | 0.164 | 0.209 | 393 | 306 | 398 |
| 240 | 0.125 | 0.159 | 456 | 361 | 475 |
| 300 | 0.1 | 0.128 | 516 | 414 | 551 |
| 400 | 0.0778 | 0.099 | 590 | 478 | 648 |
| 500 | 0.0605 | 0.077 | 673 | 557 | 763 |
| 630 | 0.469 | 0.06 | 765 | 645 | 892 |
| 800 | 0.0367 | 0.047 | 863 | 740 | 1039 |
| 1000 | 0.0291 | 0.037 | 961 | 845 | 1200 |
Noticed :
Conditions for laying in a cloverleaf formation :
Soil thermal resistivity : 120°C·cm/Watt
Burial depth : 0,5 m
Soil temperature : 15°C
Ambient temperature : 25°C
Frequency : 50 Hz
Advantages of the NA2XY cable
NA2XY cable has several advantages that make it a preferred choice for electrical distribution projects :
- Economy : lighter and less expensive than copper cables, thanks to its aluminum conductors.
- Installation versatility : suitable for installation in buildings, outdoors, in trench or in water.
- Sustainability : Heat-resistant XLPE insulation and PVC sheath providing good mechanical and chemical protection.
- International Compliance : meets IEC standards 60502-1 and European directives on safety and the environment.
- Reliability : ensures stable and secure electrical transmission over the long term, with extended lifespan.
Services & Delivery at ZMS Cable
- Personalized manufacturing service (OEM / ODM) : Custom cable design and production according to your technical specifications, with customization of the marking, Colors and packaging.
- Rapid global logistics : Shipping shipping, terrestrial or air to more than 120 pays ; Flexible delivery according to your deadlines.
- Certified quality : All products are tested before shipping ; conformity this / IEC / ISO ; test reports provided on request.
- Neat and customizable packaging : ZMS cables are packaged on wooden coils, wavy boxes or drums, with hermetically sealed ends for moisture protection. Outdoor marking can be printed on request with waterproof materials.
- Dedicated technical support : Our engineers and advisers accompany you in the choice of the electric cable most suited to your installations, in accordance with local standards.