H05Z-K cable is a low smoke, halogen-free flexible cable that meets European standards, specially designed for environments with high security requirements.
It is made of a finely twisted multi-strand bare copper conductor, surrounded by polyolefin insulation low smoke halogen free. In case of fire, it does not release toxic or corrosive gases, making it ideal for public places with high population density (like government buildings, means of transport) as well as for industrial sites where sensitive and high-value equipment is located.
This cable is resistant to oils and chemical agents, with a nominal voltage of 300/500 V and a wide operating temperature range from -40 °C to +90 °C. It can be installed in conduits, concrete gutters or other confined spaces, thus guaranteeing the safety of people in the event of evacuation due to fire.
Construction
| Driver | Flexible electrolytic copper conductive core (Class V) according to UNE-EN 60228 and in 60228 |
| Insulating | Thermostable material with a polyolefin base with low smoke and corrosive gas emissions, type El-5 according to UNE 21027-9 et HD 22.9S3 :2007 |
| ZMS CABLE is able to manufacture custom H05Z-K cables, according to the customer's technical needs. | |
Application
- Wiring of public buildings (hospitals, schools, stations, airports)
- Installations in public transport vehicles
- Electronic or chemical industries, areas with high density of sensitive equipment
- Installation in conduits, chute, or concrete sheaths
Standard
VDE-0295 Class-5, IEC 60228 Cl-5, VDE-0282 Part-9
Settings
| Product category | Unipolar wire |
| Tension nominale | Uo/U 300/500 V |
| Test voltage | 2500 V |
| Driver resistance | Class compliant 5 from the rules of VDE 0295 |
| Operating temperature range | Installation mobile : of -5 °C to +90 °C |
| Installation fixe : of -40 °C to +90 °C | |
| Maximum short-circuit temperature | 260 °C |
| Isolation resistance | Complies with the part 9 from the rules of VDE 0282 has 90 °C |
| Minimal curvature radius | Installation fixe : |
| Cable outer Ø ≤ 8 mm : 4 × external Ø | |
| outer Ø of the cable > 8 mm to 12 mm : 5 × external Ø | |
| outer Ø of the cable > 12 mm : 6 × external Ø | |
| Installation mobile : 15 × outer Ø of the cable | |
| Resistance to flame and fire propagation | Compliant with IEC standard 60332 |
| Radiation resistance | ≤ 20 × 10⁶ CJ / KG (≤ 20 MRAD) |
| Cable lengths | Available in several standard lengths, with possibility of personalized cutting according to customer needs. |
Technical data
| AWG/MCM | Number of conductors × Nominal section (mm2) | Nominal exterior (inches) | Nominal exterior (mm) | Weight of copper (lbs / 1000 feet) | Total weight (lbs / 1000 feet) |
| 20 AWG | 1 X 0,50 | 0.102 | 2.6 | 3 | 6 |
| 18 AWG | 1 X 0,75 | 0.110 | 2.8 | 5 | 7 |
| 17 AWG | 1 X 1,00 | 0.114 | 2.9 | 6 | 9 |
| 16 AWG | 1 X 1,50 | 0.138 | 3.5 | 10 | 13 |
| 14 AWG | 1 X 2,50 | 0.169 | 4.3 | 16 | 21 |
| 12 AWG | 1 X 4,00 | 0.193 | 4.9 | 26 | 30 |
| 10 AWG | 1 X 6,00 | 0.217 | 5.5 | 39 | 44 |
| 8 AWG | 1 X 10,00 | 0.280 | 7.1 | 64 | 74 |
| 6 AWG | 1 X 16,00 | 0.331 | 8.4 | 103 | 114 |
| 4 AWG | 1 X 25,00 | 0.417 | 10.6 | 161 | 195 |
| 2 AWG | 1 X 35,00 | 0.476 | 12.1 | 225 | 225 |
| 1 AWG | 1 X 50,00 | 0.567 | 14.4 | 322 | 355 |
| 2/0 AWG | 1 X 70,00 | 0.654 | 16.6 | 451 | 503 |
| 3/0 AWG | 1 X 95,00 | 0.614 | 15.6 | 612 | 671 |
| 4/0 AWG | 1 X 120,00 | 0.669 | 17.0 | 773 | 791 |
| 300 MCM | 1 X 150,00 | 0.748 | 19.0 | 966 | 1073 |
| 350 MCM | 1 X 185,00 | 0.827 | 21.0 | 1191 | 1409 |
| 500 MCM | 1 X 240,00 | 0.945 | 24.0 | 1545 | 2022 |
H05Z-K vs other common cables
| Comparison criteria | H05Z-K | H07Z-K | H05V-K | H07V-K | H07RN-F | Nym |
| Tension nominale | 300/500 V | 450/750 V | 300/500 V | 450/750 V | 450/750 V | 300/500 V you 450/750 V |
| Driver type | Soft multi-strand copper | Soft multi-strand copper | Soft multi-strand copper | Soft multi-strand copper | Soft multi-strand copper | Rigid or stranded copper |
| Insulation material | Halogen-free, low smoke (LSZH / Hffr) | Halogen-free, low smoke (LSZH / Hffr) | PVC (Vinyl polychloride) | PVC (Vinyl polychloride) | Elastomeric rubber | PVC (sheath and insulation) |
| Fire resistance | Good (IEC 60332-1) | Excellent (IEC 60332-1) | Average | Average | Excellent | Average |
| Halogen content | Halogen-free (IEC 60754-1/2) | Halogen-free (IEC 60754-1/2) | Contains halogens | Contains halogens | Contains halogens | Contains halogens |
| Smoke broadcast | Weak (IEC 61034) | Weak (IEC 61034) | High | High | Average | High |
| Flexibility | Very flexible | Very flexible | Very flexible | Very flexible | Extremely flexible | Not very flexible |
| Temperature range | -30° C to +70 ° C | -30°C to +90°C | -5° C to +70 ° C | -5° C to +70 ° C | -25°C to +90°C | -5° C to +70 ° C |
| Typical applications | Secure interior wiring, control circuits | Fixed installations in public and industrial buildings | Wiring of domestic appliances | Industrial panels and installations | Mobile devices, construction sites | Fixed installations in buildings |
| Type of installation | Fixed installation indoors (not buried) | Fixed indoor/outdoor installation | Installation in a dry environment, surface or conduit | Installation in a dry environment, surface or conduit | Pose mobile, outdoor and damp | Recessed installation, wall/floor/duct |
| Standards | IN 50525-3-31, IEC 60332-1, IEC 60754, IEC 61034 | IN 50525-3-31, IEC 60332-1, IEC 60754, IEC 61034 | IN 50525-2-31 / IEC 60227-3 | IN 50525-2-31 / IEC 60227-3 | IN 50525-2-21 / IEC 60245-4 | VDE 0250, HD 21.4, IEC 60227 |
Key Benefits of ZMS Cable H05Z-K Cable
- Environmentally friendly materials, halogen-free
- Excellent fire safety : does not emit opaque smoke or toxic gases
- Great flexibility : ease of handling and installation
- Available in several sections (of 0,5 has 10 mm²) and in various colors
- Customization possible : lengths, colors, packaging according to your needs