- Oil resistant and fireproof, with an extended lifespan of 30 %.
- Conception flexible, Ray of curvature of only 7,5 times the diameter.
- CE/TÜV/VDE certifications, compatible for global use.
- Reinforced sheath and anti-Traction structure, increased mechanical resistance of 50 %.
- Custom cable service by ZMS Cables.
Click now to obtain the specifications and the price of the H05V-K cable adapted to your needs !
Table of Contents
ToggleProduct description
The H05V-K cable is a flexible copper driver cable with PVC insulation, Designed for the transport of energy or signals in industrial distribution, Electric cabinets and low voltage equipment. It is designed for a nominal voltage of 300/500V (section ≤1,5 mm²) ou 450/750V (section ≥1,5 mm²). Its multi -curriculum driver ensures a low radius of curvature, Ideal for wet environments, exposed to oils or requiring frequent mobile installations.
Construction
Component | Material and specifications |
Driver | Multibrical Copper Copper (Class 5), section of 0,5 has 2,5 mm² (tortured with 34 son of 0,2 mm) |
Isolation | PVC (Thickness in accordance with IEC 60227, par ex. pour 0,75 mm², insulation thickness ≥ 0,5 mm), Flexible color coding |
Sheath | Light PVC Type TM2 (Thickness ≥ 0,6 mm, IN 50363-3), Outside diameter : 3,2 has 6,5 mm |
Without filling layer | Suitable for monoconductor or biconductor structures |
Application
- Industrial distribution : Internal wiring of electric cabinets, Distribution tables and automation equipment.
- Machines mobiles : Suitable for industrial robots, mechanical arms and chain systems subjected to frequent flexions.
- Renewable energies : Used in solar power plants (Water and weather resistant models) and wind systems for intermodular connections.
- Demanding environments : Suitable for wet workshops and exposed to oils, To CVC systems (HVAC) and to rail equipment.
Strengths of the Personalization Service
- Flexible parameters : Nominal voltage customization (300/500V ou 450/750V), of the temperature range (Up to 120 ° C) and traction elements.
- Quick response to export markets : CE/TÜV/VDE certifications for compatibility with European equipment and export needs.
Standard
VDE-0281 H05V-K; IN 50525-2-21; RoHS 3; IEC 60332-1-2
Key settings (NORME IEC)
Setting | Typical value / Beach |
Tension nominale | 300/300 V |
Conductor Section | 0,5-2,5 mm² |
Driver's electrical resistance (20℃) | ≤ 39,0 Ω/km (0,5 mm²) – ≤ 7,41 Ω/km (2,5 mm²) |
Isolation resistance | ≥ 0,010 TΩ·km (70℃) |
Continuous service temperature | -25℃ – +70℃ |
Short circuit temperature | +160℃ (5 seconds) |
Radius of curvature | 4 × cable diameter (installation fixe) |
Sheath tensile resistance | ≥ 10 N/mm² |
Flame delay classification | Compliant with IEC 60332-1-2 (vertical combustion test on a single cable) |
Masse | 15-40 kg/km (According to the section) |
Technical data
Number of drivers x nominal section in mm² | Approximate exterior diameter of the cable | Approximate cable weight |
2 x 0.5 | 2.1 | 8.0 |
2 x 0.75 | 2.3 | 12.0 |
2 x 1 | 2.5 | 14.0 |
2 x 1.5 | 3.1 | 20.0 |
2 x 2.5 | 3.6 | 32.0 |
2 x 4 | 4.5 | 46.0 |
2 x 6 | 5.2 | 65.0 |
2 x 10 | 6.7 | 113.0 |
2 x 16 | 8.0 | 170.0 |
2 x 25 | 9.6 | 260.0 |
2 x 35 | 11.1 | 360.0 |
2 x 50 | 14.5 | 515.0 |
2 x 70 | 15.1 | 710.0 |
2 x 95 | 19.4 | 940.0 |
2 x 120 | 21.2 | 1180.0 |
2 x 150 | 25.6 | 1481.0 |
2 x 185 | 26.5 | 2040.0 |
2 x 240 | 30.5 | 2620.0 |
Current capacity analysis (IEC 60364-5-52)
Mode d’installation | 0,75 mm² (A) | 1,5 mm² (A) |
Open -air (Type A) | 12 | 16 |
In a conduit (Type B1) | 9,5 | 13 |
Built into a wall (Type D2) | 7,5 | 10 |
Noticed : Test conditions based on an ambient temperature of 30 ° C, a driver's temperature of 70 ° C, and a single -phase system in alternating current. |
Thermal performance analysis
Temperature elevation curve (according to IEC 60287) :
Load current (A) | Temperature elevation in the stable state (ΔT) | Time to reach 90 ° C |
16 A | 40°C | Continuously safe operation |
25 A (surcharge) | 65°C | 8 minutes |
Mechanical performance tests
Essay | Result | Normative requirement |
Resistance to the tear of the sheath | 12 N/mm | ≥ 10 N/mm (IN 50363-3) |
Abrasion resistance | 100 cycles (No perforation of the sheath) | IN 50396 |
Low -temperature flexion | Successful test at -25 ° C (No cracks) | IEC 60811-202 |
Environmental adaptability
Environmental challenges | Solution du H05V-K | Comparison with other cables |
Wet environment | PVC sheath with a water absorption rate < 0,8% (IEC 60811-403) | Rubber cables : water absorption < 0,3% |
Chemical corrosion | Resistance limited to pH environments 5 has 9 (Acids and low bases) | Silicone cables : resistance to pH environments 2 has 12 |
UV exposure | Not recommended for prolonged outdoor exposure | XLPE cables : Possibility of adding carbon black for better UV resistance |
Bending lifetime | Until 10 000 cycles (IN 50396) | Rubber cables : until 50 000 cycles |
Comparaison du câble H05V-K avec d'autres câbles similaires
Features | H05V-K | H07RN-F (Rubber cable) | Sihf (Silicone cable) | XLPE-insulated |
Standards | IEC 60227 | IEC 60245 | IEC 60684 | IEC 60502-1 |
Driver | Multibrical copper class 5 (high flexibility) | Multibrical copper class 5 | Polly -tinned copper 2 | Copper class 1/2 |
Isolation | PVC | EPR rubber | Silicone | Cross-linked polyethylene (XLPE) |
Outer sheath | PVC | Neoprene rubber | Fiberglass + silicone | PVC or LSZH |
Temperature range | -25℃ to +70 ℃ | -40℃ to +90 ℃ | -60℃ at +180 ℃ | -40℃ to +90 ℃ |
Flame resistance | IEC 60332-1-2 (Single cable combustion) | IEC 60332-1-2 | IEC 60332-3-22 (bundle combustion) | IEC 60332-3-22 |
Oil resistance | Weak (Tested only with MRI 901) | Excellent (compliant with MRI 903) | Excellent | Good |
Typical applications | Internal wiring of household appliances / installations basse tension | Mobile equipment / temporary food | High temperature industrial equipment | Electrical distribution networks |
Relative cost | 1.0 (reference) | 2.0-2.5 | 4.0-5.0 | 1.5-2.0 |
Advantages of ZMS H05V-K cable
- Optimal flexibility : Finely signed copper driver + low radius of curvature (6x Ø an installation fixe, 10x Ø an installation mobile), Ideal for limited spaces and frequent flexion applications.
- Excellent environmental resistance : Oil resistant, flame (IEC 60332-1), and supporting extreme temperatures (-45° C at 120 ° C), Designed for demanding industrial environments.
- Security and Compliance : CE certified, CCC, TÜV, halogen-free (Compliant with the ROHS directive) for a reduction in toxicity in the event of a fire, adapted to international markets.
- Sustainability and mechanical resistance : Reinforced sheath + traction elements (galvanized steel cable / fibres Kevlar), offender 50 % additional abrasion resistance and extended lifespan.
- Personalization service : ZMS Cable offers tailor -made options : sections of 0,5 has 70 mm², sheath colors, Flame delay levels, To meet the specific needs of each application.