H05V-K cable

  • Oil resistant and fireproof, with an extended lifespan of 30 %.
  • Conception flexible, Ray of curvature of only 7,5 times the diameter.
  • CE/TÜV/VDE certifications, compatible for global use.
  • Reinforced sheath and anti-Traction structure, increased mechanical resistance of 50 %.
  • Custom cable service by ZMS Cables.

Click now to obtain the specifications and the price of the H05V-K cable adapted to your needs !

Get a Quote

Product description

The H05V-K cable is a flexible copper driver cable with PVC insulation, Designed for the transport of energy or signals in industrial distribution, Electric cabinets and low voltage equipment. It is designed for a nominal voltage of 300/500V (section ≤1,5 mm²) ou 450/750V (section ≥1,5 mm²). Its multi -curriculum driver ensures a low radius of curvature, Ideal for wet environments, exposed to oils or requiring frequent mobile installations.

Construction

Component Material and specifications
Driver Multibrical Copper Copper (Class 5), section of 0,5 has 2,5 mm² (tortured with 34 son of 0,2 mm)
Isolation PVC (Thickness in accordance with IEC 60227, par ex. pour 0,75 mm², insulation thickness ≥ 0,5 mm), Flexible color coding
Sheath Light PVC Type TM2 (Thickness ≥ 0,6 mm, IN 50363-3), Outside diameter : 3,2 has 6,5 mm
Without filling layer Suitable for monoconductor or biconductor structures

Application

  • Industrial distribution : Internal wiring of electric cabinets, Distribution tables and automation equipment.
  • Machines mobiles : Suitable for industrial robots, mechanical arms and chain systems subjected to frequent flexions.
  • Renewable energies : Used in solar power plants (Water and weather resistant models) and wind systems for intermodular connections.
  • Demanding environments : Suitable for wet workshops and exposed to oils, To CVC systems (HVAC) and to rail equipment.

Strengths of the Personalization Service

  • Flexible parameters : Nominal voltage customization (300/500V ou 450/750V), of the temperature range (Up to 120 ° C) and traction elements.
  • Quick response to export markets : CE/TÜV/VDE certifications for compatibility with European equipment and export needs.

Standard

VDE-0281 H05V-K; IN 50525-2-21; RoHS 3; IEC 60332-1-2

Key settings (NORME IEC)

Setting Typical value / Beach
Tension nominale 300/300 V
Conductor Section 0,5-2,5 mm²
Driver's electrical resistance (20℃) ≤ 39,0 Ω/km (0,5 mm²) – ≤ 7,41 Ω/km (2,5 mm²)
Isolation resistance ≥ 0,010 TΩ·km (70℃)
Continuous service temperature -25℃ – +70℃
Short circuit temperature +160℃ (5 seconds)
Radius of curvature 4 × cable diameter (installation fixe)
Sheath tensile resistance ≥ 10 N/mm²
Flame delay classification Compliant with IEC 60332-1-2 (vertical combustion test on a single cable)
Masse 15-40 kg/km (According to the section)

Technical data

Number of drivers x nominal section in mm²Approximate exterior diameter of the cableApproximate cable weight
2 x 0.52.18.0
2 x 0.752.312.0
2 x 12.514.0
2 x 1.53.120.0
2 x 2.53.632.0
2 x 44.546.0
2 x 65.265.0
2 x 106.7113.0
2 x 168.0 170.0
2 x 259.6260.0
2 x 3511.1360.0
2 x 5014.5515.0
2 x 7015.1710.0
2 x 9519.4940.0
2 x 12021.21180.0
2 x 15025.61481.0
2 x 18526.52040.0
2 x 24030.52620.0

Current capacity analysis (IEC 60364-5-52)

Mode d’installation 0,75 mm² (A) 1,5 mm² (A)
Open -air (Type A) 12 16
In a conduit (Type B1) 9,5 13
Built into a wall (Type D2) 7,5 10
Noticed : Test conditions based on an ambient temperature of 30 ° C, a driver's temperature of 70 ° C, and a single -phase system in alternating current.

Thermal performance analysis

Temperature elevation curve (according to IEC 60287) :
Load current (A) Temperature elevation in the stable state (ΔT) Time to reach 90 ° C
16 A 40°C Continuously safe operation
25 A (surcharge) 65°C 8 minutes

Mechanical performance tests

Essay Result Normative requirement
Resistance to the tear of the sheath 12 N/mm ≥ 10 N/mm (IN 50363-3)
Abrasion resistance 100 cycles (No perforation of the sheath) IN 50396
Low -temperature flexion Successful test at -25 ° C (No cracks) IEC 60811-202

Environmental adaptability

Environmental challenges Solution du H05V-K Comparison with other cables
Wet environment PVC sheath with a water absorption rate < 0,8% (IEC 60811-403) Rubber cables : water absorption < 0,3%
Chemical corrosion Resistance limited to pH environments 5 has 9 (Acids and low bases) Silicone cables : resistance to pH environments 2 has 12
UV exposure Not recommended for prolonged outdoor exposure XLPE cables : Possibility of adding carbon black for better UV resistance
Bending lifetime Until 10 000 cycles (IN 50396) Rubber cables : until 50 000 cycles

Comparaison du câble H05V-K avec d'autres câbles similaires

FeaturesH05V-KH07RN-F (Rubber cable)Sihf (Silicone cable)XLPE-insulated
StandardsIEC 60227IEC 60245IEC 60684IEC 60502-1
DriverMultibrical copper class 5 (high flexibility)Multibrical copper class 5Polly -tinned copper 2Copper class 1/2
IsolationPVCEPR rubberSiliconeCross-linked polyethylene (XLPE)
Outer sheathPVCNeoprene rubberFiberglass + siliconePVC or LSZH
Temperature range-25℃ to +70 ℃-40℃ to +90 ℃-60℃ at +180 ℃-40℃ to +90 ℃
Flame resistanceIEC 60332-1-2 (Single cable combustion)IEC 60332-1-2IEC 60332-3-22 (bundle combustion)IEC 60332-3-22
Oil resistanceWeak (Tested only with MRI 901)Excellent (compliant with MRI 903)ExcellentGood
Typical applicationsInternal wiring of household appliances / installations basse tensionMobile equipment / temporary foodHigh temperature industrial equipmentElectrical distribution networks
Relative cost1.0 (reference)2.0-2.54.0-5.01.5-2.0

Advantages of ZMS H05V-K cable

  • Optimal flexibility : Finely signed copper driver + low radius of curvature (6x Ø an installation fixe, 10x Ø an installation mobile), Ideal for limited spaces and frequent flexion applications.
  • Excellent environmental resistance : Oil resistant, flame (IEC 60332-1), and supporting extreme temperatures (-45° C at 120 ° C), Designed for demanding industrial environments.
  • Security and Compliance : CE certified, CCC, TÜV, halogen-free (Compliant with the ROHS directive) for a reduction in toxicity in the event of a fire, adapted to international markets.
  • Sustainability and mechanical resistance : Reinforced sheath + traction elements (galvanized steel cable / fibres Kevlar), offender 50 % additional abrasion resistance and extended lifespan.
  • Personalization service : ZMS Cable offers tailor -made options : sections of 0,5 has 70 mm², sheath colors, Flame delay levels, To meet the specific needs of each application.

    Request a free quote, we will respond to you within 24 hours.

    Your Email*:

    Your Name*:

    Your Country:

    Your Phone*:

    Your message*: