GYTA53 fiber optic cable is a reinforced version of GYTA cable, specially designed for outdoor installations in demanding environments. Unlike standard GYTA, which offers a simple outer sheath, The GYTA53 features steel strip armor and a double protective sheath, giving it excellent mechanical resistance, protection against humidity and perfect adaptation to direct buried installation. It is ideal for long distance networks, industrial zones and high-stress environments.
Construction
| Component | Description technique |
| Fiber optics | Single-mode or multi-mode fibers (most common type G.652D) |
| Gel filling (free tube) | Water repellent gel in the tubes to block water and protect the fiber |
| Plastic tubes | PBT tubes arranged around the central element |
| Central element | Steel wire (steel wire), PE sheathed for mechanical strength |
| Filler wires | Filling materials to ensure the roundness and stability of the structure |
| Water Blocking Tape | Absorbent tape to prevent water infiltration |
| Plasticized aluminum strip (APL) | Longitudinal metal casing for additional moisture barrier |
| Inner sheath (internal) | Polyethylene sheath (PE) around the central structure |
| Armor | Double-sided plasticized steel strip (PSP), applied longitudinally |
| Outer sheath | Black PE outer sheath, UV resistant, to humidity and crushing |
Standard
IEC 6079, IT-T G.652/G.657, ISO/IEC 11801,YD/T 901
Settings
| Structure | Description technique |
| Fiber type | Monomode (G.652/G.657) or multimode (OM1/OM2), number of fibers : 2 has 432 |
| Loose tube (PBT) | Diameter ≈ 2.1mm, thickness 0.3±0.05mm, filled with water-repellent gel |
| Central reinforcement element | Phosphated steel wire or aramid wire, tensile strength : 3000 N (court terme), 1000 N (long terme) |
| Filling | Blocking gel + PBT fillers (selon tube name) |
| Inner sheath | Medium density polyethylene (MDPE), thickness ≈ 0.8–0.9mm, with PLA layer (aluminum/polyethylene) |
| Armor | Corrugated steel strip (PSP), thickness ≈ 0.15mm, protection against rodents and crushing |
| Outer sheath | Black polyethylene (PE), thickness ≈ 1.6–1.8mm, UV and weather resistant |
| Setting | Unit | Life cycle | 2–24F | 36F | 48F | 72F | 96F |
| Min tensile strength. | N | court terme | 3000 | 3000 | 3000 | 3000 | 3000 |
| long terme | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Min crushing load. | N/100 mm | court terme | 3000 | 3000 | 3000 | 3000 | 3000 |
| long terme | 1000 | 1000 | 1000 | 1000 | 1000 | ||
| Minimal curvature radius | mm | court terme | 20D | 20D | 20D | 20D | 20D |
| long terme | 10D | 10D | 10D | 10D | 10D | ||
| Storage temperature | °C | -40 has +60 | |||||
Optical characteristics
| Setting | Unit | G.652 | 62,5/125 μm | 50/125 μm | |||
| Mitigation | dB/km | 1310 nm | ≤0,36 | 850 nm | ≤3,0 | 850 nm | ≤3,0 |
| 1550 nm | ≤0,22 | 1310 nm | ≤1,0 | 1310 nm | ≤1,0 | ||
| Bandwidth | MHz·km | — | — | 850 nm | ≥600 | 850 nm | ≥200 |
| — | — | 1300 nm | ≥1200 | 1300 nm | ≥600 | ||
| Numerical aperture | THAT | — | 0,275 ± 0,015 | 0,200 ± 0,015 | |||
| Cutoff wavelength | λcc (nm) | ≤1260 | — | — | |||
Technical data
| Number of fibers | Part number | Application | Cable diameter (mm) | Weight (kg/km) |
| Fibre monomode 9/125 µm OS2 | ||||
| 2F | GYTA53-OS2-2F | Direct installation in the ground | 12.5 | 200 |
| 4F | GYTA53-OS2-4F | Direct installation in the ground | 12.5 | 200 |
| 6F | GYTA53-OS2-6F | Direct installation in the ground | 12.5 | 200 |
| 8F | GYTA53-OS2-8F | Direct installation in the ground | 12.5 | 200 |
| 12F | GYTA53-OS2-12F | Direct installation in the ground | 12.5 | 200 |
| 24F | GYTA53-OS2-24F | Direct installation in the ground | 12.5 | 200 |
| 36F | GYTA53-OS2-36F | Direct installation in the ground | 12.5 | 200 |
| 48F | GYTA53-OS2-48F | Direct installation in the ground | 12.5 | 210 |
| 72F | GYTA53-OS2-72F | Direct installation in the ground | 14 | 210 |
| 96F | GYTA53-OS2-96F | Direct installation in the ground | 14.5 | 230 |
| Fibre multimode 62,5/125 µm OM1 | ||||
| 2F | GYTA53-OM1-2F | Direct installation in the ground | 12.5 | 200 |
| 4F | GYTA53-OM1-4F | Direct installation in the ground | 12.5 | 200 |
| 6F | GYTA53-OM1-6F | Direct installation in the ground | 12.5 | 200 |
| 8F | GYTA53-OM1-8F | Direct installation in the ground | 12.5 | 200 |
| 12F | GYTA53-OM1-12F | Direct installation in the ground | 12.5 | 200 |
| 24F | GYTA53-OM1-24F | Direct installation in the ground | 12.5 | 200 |
| 36F | GYTA53-OM1-36F | Direct installation in the ground | 12.5 | 200 |
| 48F | GYTA53-OM1-48F | Direct installation in the ground | 12.5 | 210 |
| 72F | GYTA53-OM1-72F | Direct installation in the ground | 14 | 210 |
| 96F | GYTA53-OM1-96F | Direct installation in the ground | 14.5 | 230 |
| Fibre multimode 50/125 µm OM2 | ||||
| 2F | GYTA53-OM2-2F | Direct installation in the ground | 12.5 | 200 |
| 4F | GYTA53-OM2-4F | Direct installation in the ground | 12.5 | 200 |
| 6F | GYTA53-OM2-6F | Direct installation in the ground | 12.5 | 200 |
| 8F | GYTA53-OM2-8F | Direct installation in the ground | 12.5 | 200 |
| 12F | GYTA53-OM2-12F | Direct installation in the ground | 12.5 | 200 |
| 24F | GYTA53-OM2-24F | Direct installation in the ground | 12.5 | 200 |
| 36F | GYTA53-OM2-36F | Direct installation in the ground | 12.5 | 200 |
| 48F | GYTA53-OM2-48F | Direct installation in the ground | 12.5 | 210 |
| 72F | GYTA53-OM2-72F | Direct installation in the ground | 14 | 210 |
| 96F | GYTA53-OM2-96F | Direct installation in the ground | 14.5 | 230 |
Advantages of GYTA53 fiber optic cable
Reinforced mechanical protection
The double-layer shielding structure (steel belt + aluminum-plastic belt) effectively resists lateral pressure, à l'extrusion et aux dommages causés par les rongeurs.
High tensile and compressive strength
Short-term tensile/compressive strength can reach 3000 N, ce qui peut garantir la stabilité du signal même lorsqu'il est directement enterré.
Excellentes performances d'étanchéité à l'humidité
Waterproof internal glue, le ruban aluminium-plastique et l'armure métallique fonctionnent ensemble pour empêcher l'humidité, suitable for high humidity or underground environments.
Reliable long distance transmission
G.652 single-mode optical fiber, attenuation ≤ 0,36 dB/km, suitable for long distance backbone networks.
Gyty53 vs gyta53 vs gyta vs gyts
| Criteria / Model | GYTY53 | GYTA53 | WITH | Consonant |
| Central element | Phosphated steel wire | Phosphated steel wire | Phosphated steel wire | Phosphated steel wire |
| Internal sheath | Polyethylene (PE) | Plasticized aluminum strip (APL) + PE hens | Polyethylene (PE) | Polyethylene (PE) |
| Moisture-wicking layer | Sans aluminium, protection provided only by PSP | APL + PSP steel strip : double anti-humidity barrier | APL only | Gel Filler + ruban polyester |
| Armor | Double-sided plasticized steel strip (PSP), longitudinal installation | Double-sided plasticized steel strip (PSP), longitudinal installation | No armor | Simple PSP steel strip armor |
| Outer sheath | Polyethylene (PE) | Polyethylene (PE) | Polyethylene (PE) | Polyethylene (PE) |
| Recommended installation | Direct burial / conduit | Direct burial in a humid environment / conduit / flooded area | Conduit / air | Conduit / general outdoor use |
| Waterproofing | Average – protection via steel band | Excellent – effective double barrier against water and humidity | Average – APL barrier | Medium – barrier by blocking gel |
| Environmental resistance | Good – pressure resistant, suitable for various terrains | Excellent – high level of protection against humidity and corrosion | Average – recommended in urban areas | Medium – not recommended for very humid environments |
Why choose the Gyta53 ZMS ?
Extreme robustness : double weave + double gaine + central reinforcement = optimal protection against crushing, traction, humidity and rodents.
Secure optical performance : low attenuation and international standard fibers ensure stable transmission.
Flexibility & compatibility : available in several configurations (2–432 cores), in single or multimode.
Bespoke customization : ideal for specific projects thanks to OEM/ODM services.
Transport – ZMS CABLE
- The cables are packed on treated wooden towns or metal drums, With plastic film or BOPP for humidity protection.
- We offer maritime transport in 20ft or 40ft container, Depending on the control volume.
- Land transport is available for regional or local deliveries (Depending on the destinations).
- On demand, We also provide air transport for urgent orders.
- All necessary export documents are provided : commercial invoice, packing list, original certificate, documents douaniers, etc.