EXVB and EAXVB cables

Rigid cable EXVB cable
  • 1KV copper exvb cable for outdoor and underground installations
  • Exvb XLPE/PVC electrical cable resistant to humidity and mechanical stresses
  • Economic alternative to copper cable : Custom aluminum eaxvb cable
  • Exvb and EAXVB cables comply with IEC standards for electrical distribution 0,6/1 kV
  • ZMS Cable - Specialist in custom exvb cables adapted to all your technical needs
  • Low voltage underground cables ready to install for fixed installations, Robust and secure

Get a Quote

The EXVB cable is a low voltage power cable (0,6/1 kV) With copper and XLPE insulation driver, Designed for fixed installations. It is ideal for outdoor pose, underground or in wet environments, in particular for the connection between the public network and the electrical installations of the residential buildings, industrial or tertiary. Robust and reliable, It resists mechanical constraints and humidity.

EAXVB cable is an economical alternative to EXVB cable, using an aluminum driver instead of copper. It is suitable for fixed installations outdoors or in pipeline, especially when cost reduction is an important criterion.

Construction

StructureExvb cableEAXVB cable
DriverRigid or wired copper driver, class 1 or class 2Rigid or wired aluminum driver, class 1 or class 2
IsolationXLPE (cross-linked polyethylene)
Inner sheath / fillingPVC (polyvinyl chloride)
Outer sheathPVC (polyvinyl chloride)
Tension nominale0,6/1 kV
Applicable standardsIN 60332-1, IEC 60502-1, etc.HD 603 Part 5/SECT.A, IEC 60502-1, etc.
Areas of applicationExterior installations, underground or humid and industrial environments. Suitable for environments with high mechanical constraints.Fixed installation in the ground, conduits or concrete. Suitable for low -voltage distribution systems sensitive to costs.

Applications of EXVB and EAXVB cables

Exb

  • Outdoor, underground or in wet environments
  • Ideal for the connection between the public network and the electrical tables
  • Suitable for residential facilities, industrial and tertiary
  • Direct trench installation, Without the need for additional protection

EAXVB

  • Outdoor or pipe use
  • Recommended for secondary networks, subdivisions or fixed installations
  • Economy solution with aluminum driver

Standard

NBN C30-004 F2, IEC 60332-3-24, HD 308 S2

Settings - EXVB and EAXVB cables

Tension nominale (U₀/U) 0,6/1 kV
Maximum system voltage 1,2 kV
Alternating current trial voltage 4 kV
Maximum driver's continuous service temperature 90 °C
Maximum short-circuited driver temperature (5 s max.) 250 °C
Maximum overload temperature (until 100 h/an) 130 °C
Minimum installation temperature -5 °C
Temperature range in service from -35 ° C to +90 ° C
Minimal curvature radius Unipolar cable : 15 × outside diameter
Multipolar cable : 12 × outside diameter

Technical data

Section (mm2) Resistance at 20°C (Ω/km) Outdoor diameter (mm) Weight(kg/km)
1 x 1.5 12,1 4,81 36
1 x 2.5 7,41 5,06 45
1 x 4 4,61 5,55 61
1 x 6 3,08 6,35 86
1 x 10 1,83 7,10 128
1 x 16 1,15 8,36 184
1 x 25 0,727 9,88 281
1 x 35 0,524 11,00 370
1 x 50 0,387 12,40 527
1 x 70 0,268 14,70 743
1 x 95 0,193 16,70 1008
1 x 120 0,153 18,10 1210
1 x 150 0,124 20,34 1513
1 x 185 / 22,60 1836
1 x 240 0,0775 25,25 2466
1 x 300 / 28,70 3000
1 x 400 / 32,60 3888
2 x 1.5 12,1 8,05 93
2 x 2.5 7,41 8,07 119
2 x 4 4,61 9,76 163
2 x 6 3,08 11,10 221
2 x 10 1,83 12,64 325
2 x 16 1,15 15,86 527
2 x 25 0,727 20,30 845
2 x 35 0,524 21,40 1039
3 x 1.5 12,1 8,52 110
3 x 2.5 7,41 9,22 144
3 x 4 4,61 10,23 199
3 x 6 3,08 11,75 274
3 x 10 1,83 13,47 416
3 x 16 1,15 16,88 666
3 x 25 0,727 20,21 1011
3 x 35 0,524 22,90 1334
4 x 1.5 12,1 9,25 132
4 x 2.5 7,41 10,04 175
4 x 4 4,61 11,17 245
4 x 6 3,08 12,94 345
4 x 10 1,83 14,83 522
4 x 16 1,15 18,50 835
4 x 25 0,727 22,55 1295
4 x 35 0,524 25,30 1698
5 x 1.5 12,1 10,07 160
5 x 2.5 7,41 11,01 214
5 x 4 4,61 12,20 298
5 x 6 3,08 14,21 421
5 x 10 1,83 16,36 643
5 x 16 1,15 20,25 1019
5 x 25 0,727 25,30 1617
5 x 35 0,524 28,00 2085

Benefits

Advantages of the EXVB cable

  • High mechanical resistance and excellent hold in aggressive environment
  • Perfectly suited to direct burial without additional protection
  • Robust insulation and sheath against humidity, Shocks and chemicals
  • Remarkable longevity for long -term reliability
  • Custom cable service by ZMS Cables : dimensions, marking, Personalized packaging according to your projects

EAXVB cable advantages

  • Outdoor or pipe use
  • Recommended for secondary networks, subdivisions or fixed installations
  • Economy solution with aluminum driver

    Request a free quote, we will respond to you within 24 hours.

    Your Email*:

    Your Name*:

    Your Country:

    Your Phone*:

    Your message*: